Run 68 Analysis Task List
| Tasks necessary for Reprocessing | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| Start task list | you're looking at it | MF | completed |
| Templates | either construct or improve analytical parameters | NM | completed |
| Channel balancing | method, time/dataset/energy dependence, calculate | MF | completed |
| Trigger mask? | found out we don't have more than DCRC for trigger source | AV | completed |
| NaI timing windows | optimize in processing | AV | completed |
| Series-dependent relative calibration | do we want this? autoprocessing has the ability | retired | |
| ADC min/max, bin | low priority. add to processing. | unassigned | |
| Sloped BS subtract? | fancy, requires study. consider for later processing. | NM | postponed |
| OF settings | Choose OF search window and whether OF algorithm should be modified | NM | completed |
| Add PT bs/bspost rqs | Can do equivalent with existing rqs. | retired | |
| Deal with first-8-bin glitch | zero out in trace during processing? dE<3 eV, probably doesn't matter. | NM | completed |
| Select/prioritize data | what subset of data should be reprocessed? | MF | completed |
| Modify autoproc | Allow input list of series to proc. (is this necessary?) | AV | retired |
| Channel balancing for other biases | check -80V, -40V, +40V | MF | assigned |
| Further OF/template options? | unassigned | ||
| Calibration | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| Am calibration | MF | completed | |
| Compton step calibration | MF | started | |
| Calibration stability/correction | MF | assigned | |
| Resolution as a function of energy | MF | started | |
| Data Stability | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| HV bias | unassigned | ||
| Noise studies | NM | completed | |
| BS correction | baseline value tracks position in transition | NM | completed |
| Data selection cuts | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| Fiducialization | unassigned | ||
| OF/Int agreement: pileup cut | NM | completed | |
| OF/WK timing consistency cut | NM | completed | |
| OF/WKmax agreement: pileup cut | Superseded by timing consistency cut | NM | retired |
| Tail cut | NM | completed | |
| Baseline cut | NM | completed | |
| Chisquare cut for pileup | NM | completed | |
| Glitch cut | NM | completed | |
| OF/OF0 agreement: not as well motivated | Complicated by amplitude-dependent trigger times | retired | |
| Trigger burst cut | NM | completed | |
| Other quality cuts: baseline consistency, etc | unassigned | ||
| Threshold & Livetime & Efficiency | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| trigger threshold study | NM, SB | completed | |
| rate/livetime | rate/livetime (randoms/triggers, Am rate comparison) | DS | started |
| cut efficiencies | NM | completed | |
| NaI | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| relative timing & timing drift study | Some help? | AV | assigned |
| NaI energy calibration characteristics/settings | NM | started | |
| NaI glitch events | unassigned | ||
| Simulation and Background | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| Instructions for K100 Pu/Be simulation | AV | started | |
| efficiency of NaI tag for captures | AV | assigned | |
| direct neutron and other Pu/Be on backgrounds | AV | started | |
| signal model updating/plotting | AV | assigned | |
| Am-241 / Na-22 simulations? | MF | assigned | |
| Migdal effect | MF | Started | |
| Fitting and Final Analysis | |||
|---|---|---|---|
| Task | Notes | Assignee | Status |
| Burst Cut Systematics | NM | Complete | |
| New Si capture spectrum | AV,KH | In Progress | |
| ER Calibrations Write-Up | MF | In Progress | |
| Address Migdal Effect | MF | In Progress | |
| Spectrum Goodness of Fit | Chisq is sensible for comparing fits given measured spectrum. Also, generally chisq>1 when using stat uncertainty alone and <1 with systematics. | NM | In Progress |
| Table of uncertainties | NM | Complete | |