UMN CDMS Wiki archive
start › cdms › k100 › meetings › 20170504

Agenda

  • Operations
    • Run 62 (HV#4, Si) status:
    • Ge iZIP “pathfinder” - have proposed a bonding scheme to connect all 12 phonon channels for readout. Current ETA is 3.0 weeks min from now.
      • Detector has been determined to fit (tightly) in housing, may bump DIBs when cold
      • Fab still waiting for Tc verification. From Mark Platt on Tuesday: “I have been recieving mixed results on the same samples. The latest result Paul sent last night shows my TC at 32mK. I am making some new samples and sending them now that the Blue Fors is back up. I apologize for the delay in starting but I need to be sure of TC before starting this crystal. I will keep you posted. I am chomping at the bit to start this as well.”
    • Future 6“ run (1”-thick 5Q device). Detector now at UMN, needs to be wirebonded
    • Continued K100 support through both Project and Operations - assume no SNOLAB upgrade
      • exploring ideas for improvements without upgrade: float DCRCs for symmetric biasing Proposed Scheme, decrease Rshunt in SQUETs
  • Lab infrastructure
  • Processing and Analysis
    • Run 61, HV#2 (Ge) analysis
    • Run 60, 6“ detector paper - Plan to edit and publish without 5Q data
    • Run 56, iZIPv6 analysis
  • Physics
    • low-energy Comptons and n,gamma calibrations with external triggering
  • Old/continuing items:
    • DAQ and data pipe
      • DAQ upgrade - discussed with Bruno about IbIs tool development
      • Data storage and backup:
        • Need to copy all Run 60 and some Run 61 data to SLAC
      • Autoprocessing and data organization development:
        • currently autoprocessing suspended, no “official” processing for Runs 60, 61, 62
        • clean up database - some info missing. Consider adding additional info
    • Possible plan to modify DCRCs (resistor swap) so we can increase front-end gain, improve IbIs (suggestion from Bruno)
    • IF (not likely) new DCRC RevC.2 arriving from Bruce in Denver then
      • missing resistors on 3 QET channels, we've ordered some