| Teleconference link: | https://umn.zoom.us/j/8797896096 or https://umn.zoom.us/my/fritts |
| Access code: | 879-789-6096 |
Agenda
- Run 72 in progress
- Payload:
- Housing in Position 1 with Source mover, LEDs, thermometer and a test screw-terminal for NbTi
- Heatsinking added to motor coil solder joints
- G101D with Side 2 etched, Position 2. Source pointed at readout side.
- One QET wired with twisted pair instead of side coax
- External electrode in Position 3
- Side1pE not working, appears to be open. Possibly a wirebond broke.
- Fridge basically working, base around 51-56 mK.
- 1K Pot running warmer than normal, makes base temperature sensitive to LN2 Cold Trap bath fills, which is annoying
- We've increased the Still heater power twice, keeping the base low. But each time the Circulation pressures go up. It may be getting slowly worse
- Assuming that the 1K Pot was not sufficiently purged or has a bad o-ring, should be able to fix this in next cooldown
- Fridge shield built (lead on all 4 sides). This makes the Am lines much easier to see.
- Taking and analyzing data at various drifted biases
- Yesterday's -250V data shows an even lower Luke gain, implying an effective bias of 24.5 V, which is 16.5% of what we expect with a 1mm gap
- Apparent Luke Gain implies much lower biases than calculated. Example: +250V data, Luke gain implies 59.9 V, 39.5% of expected (for 1mm gap). About the same for all positive biases.
- Luke Gain even smaller for negative biases. Example: -250V data, Luke gain implies 24.5 V, 16.5% of expected. This was also seen in Run 69
- Still to do:
- initial observations suggest noise sigma is lower with lower event rate. Use source to study relation of noise to event rate.
- HV troubleshooting…
- Try using the source mover, take position-dependence data
- Weekend transfer planning.
- PuBe storage shielding
- Howitzer is good neutron shielding but not as good as red box for gamma shielding. Is it insufficient? PuBe storage measurements and analysis
- Budget overage: we have something like $20,000 we could spend on lab stuff before April 1
- Buy equipment/supplies:
- New idea: get a new LHe transfer stick? Janis standard-model (one piece) = $2200, we may want a custom model instead.
- Replacement forepump for leak detector
- This pump is discontinued - instead we shipped ours to Pfeiffer for repair
- Send out spare circulation pump for leakcheck/repair
- Two lab computers replaced
- NbTi cables for tower-free detector&cold electronics mounting
- could get 2@25-wire for 4K-CP, 2@25-wire for CP-MC. And maybe 2@25-wire, longer, to try 4K-MC (colder SQUETs)
- SQUIDs for new cold electronics
- Copper-clad NbTi bell wire for a new source mover motor - quote at $930 for one motor
- Analysis status:
- Run 71
- paper on Arxiv and submitted to NIMA
- possible followup studies. 100mm iZIP position reconstruction
- Run 68 (n,gamma with S101)
- Migdal analysis pending
- New (n,γ) simulations, modified signal shape
- NaI studies
- tried to see Si n-capture gammas with a bag of sand - nothing seen
- assessing the howitzer for PuBe storage - definitely doesn't shield gamma as well as paraffin drum and lead box
- Run 70
- analysis team includes Pramod, Matt, Zach - should coordinate, have meetings
- Need to look at the recent PuBe data, work on a low-threshold energy quantity, see if we can see a hint of (n,γ) signal. Also develop cuts and look for low-energy junk
- Will study the activation peak background
- Run 67 (USD detector with novel time-dependent gain)
- Dongming has characterized lots of microscopic processes, wants us to write a paper
- Matt working on rough model of detector behavior
- SiHV event reconstruction
- Derek working on this
- Hongguang developing connection to DMC
- Future runs?
- Re-run USD1?
- use Co source
- experiment with varying the amount of shield, distance of Ba source, see how background rate affects time variations in gain
- maybe use source mover
- Position reconstruction with source mover
- improve motor heatsinking?
- run with GeHV prototype - would probably want to rebond it for standard direct contact biasing
- some day get a SiHV prototype again, run with that
- Improved neutron calibration runs
- under discussion with Anthony - working on grant proposal for new measurements with more NaI and whatever other improvements
- more NaI coincidence detectors
- can we improve Ge?
- try again with standard bias, maybe no-tower setup?? Would this improve it?
- try polishing bias side for “true” vacuum interface?
- or - use a HVeV detector? can we get a high enough signal rate?
- or should we re-do SiHV? with one of the new “pathfinder” detectors, whichever they give to us
- Future 150mm runs
- 150mm w/phonons - we considered designing new 600mK rod to accommodate 150mm cans. Could rethink this in terms of no-tower setup maybe…
- We have 4/3-inch DIBs from TAMU - now we can house either detector for phonon readout (would need to machine faces on 4/3-inch housing for DIBs)
- S1501 and S1502 sent back to TAMU
- We have decided we can run 8 phonon channels
- Preferred DIB-pad layout: two DIBs separated by 120 degrees
- Himangshu's mask design: PDF download
- Will use existing vacuum-interface electrode, mounted on side opposite the phonon side
- Will connect directly to two DCRCs, with one diverter board to route one tower wire to HV connection
- We'll want LEDs - are there some mounted on the DIBs? We can mount external LEDs too - existing electrode has mounts.
- First 150mm phonon detector will be monolithic, but “donut+hole” arrangement (active veto) proposed as well.
- Last discussion of this was a year ago, we were aiming for May 2019 to fab a detector
- Future HVeV runs?
- Berkeley can help us with a Soudan-style housing mount (3“ or 4”?)
- then use original tower, can try different heatsinking for colder SQUID card
- would need to install optical fiber
- through top or through stripline tube?
- Should we design and build new cold hardware?
- Soudan towers didn’t perform thermally as well as they should have (graphite tubes too conductive)
- Soudan towers had requirements we can relax
- FET heat not a consideration for phonon-only devices
- Materials don’t need to be as radiopure
- Soudan tower concept
- NEXUS setup
- NbTi cable thermal conductance: G=3.11e-8*T^1.19 W/mK (for 1m, 40 wires, base = 100 mK)
- Tekdata NbTi, MDM-25 quote: ~$715 each
- Cheap ($10/inch^2) SC flex PCB inside MC can Photo
- SQUET recall
- Martin wants 5 of our 9 SQUETs sent back to Colorado. He wants good SQUIDs.
- A lot of issues to deal with:
- there are bad SQUID chips
- we need to change shunt resistances for iZIPv6 versus HV, but don't want to wirebond too many times
- some SQUETs have problems at the pins
- can we get spare SQUETs with the SQUID chips removed? Could theoretically glue good SQUID chips onto good SQUET.
- Anthony says we may be able to get alternative SQUID chips
- We have 1.5-ish months to deal with this
- Lab and infrastructure
- Leak detector: After pump rebuild, pump no longer turned. Jake and Derek fixed this problem. However, it still doesn't seem to be able to pull a good vacuum. Using scroll pump assist in order to use leak detector.


