UMN CDMS Wiki archive
start › cdms › k100 › meetings › 20160408

Agenda

  • Operations:
    • Run 57: G114 (the other iZIPv6) for HV attempt, maybe other studies, no internal source
      • Note from Paul B: this is the first AJA detector, and there are some concerns re “step coverage” and continuity. If Rn's are found to be too high (say, >1.5 Ω) then we should probably immediately deem this detector “bad” in terms of phonons at least. Could still try to test HV characteristics with charge only.
      • Wire bond repair of G114
      • One tower face broken, another repaired
      • Soudan IT4 tower now at UMN
    • Future runs: SD crystal, 6“ crystals, sidewall source, G106a with no-internal-source
  • DAQ and data pipe
    • Data storage and backup - progress
    • Code education - Matt, Nick, David to learn more about DAQ and processing code (Anthony is the only expert)
  • Analysis
    • cdmsbats audit for data analysis push (Anthony, pdf)
    • updates and planning
    • What should we plan to publish?