Agenda
- Run 71 prep
- Motorized source mover ready to go. Need to decide on initial position and placement of copper-tape blocker
- Source collimator - Nick built the holder for the bare source and a small lead collimator disk. We need a larger hole for the bare source, so need to drill a 18 mil hole in a small collimator
- will use 100mm iZIP G106a
- need a set of 3 SQUETs with four working phonon channels each, and two with working charge channels.
- we have this - just need to change two channels on one SQUET back to standard 20 mOhm shunt.
- timing: will try to start soon. Nick and Matt both leave at the end of next week for about 2 weeks.
- SQUET recall
- Martin wants 5 of our 9 SQUETs sent back to Colorado. Should keep the best four.
- actually Martin wants the best-performing SQUIDs, i.e. largest modulation depths. But we probably don't have that info.
- but we know some SQUID chips are bad:
- seems like 6 out of 36 chips are bad
- So suppose we give Martin 20 good chips - we'd be left with only 10, could run 6-channel HV but not 12-channel iZIP
- or we keep 12 good chips (say 3 perfect SQUETs) and Martin gets 18
- or we keep 16 good chips (4 perfect SQUETs) and Martin gets only 14
- need to explain the situation to Martin. Maybe he can still use damaged chips?
- We have 2-3 months to deal with this
- Analysis status:
- Run 68 (n,gamma with S101)
- Migdal analysis
- Data not yet looked at:
- Trigger study data
- Hold-time runs at different biases done, haven't looked at them yet
- Have reprocessed -80V Na data. Used -125V balancing factors, still need to check if those are optimal (if not we should redo it)
- Run 70
- Yixian working on write efficiency and checking rates of activation lines
- Pramod wants to get involved
- Need to look at the recent PuBe data, work on a low-threshold energy quantity, see if we can see a hint of n,gamma signal
- Possible heat-sinking changes for HV (phonon-only) runs:
- Disconnect 4K heatsinking and connect 4K and Still stages
- to reduce temperature at tower pins, reducing noise contribution there
- would make Still warmer but this may not be a bad thing
- Disconnect 600mK rod and connect Still and Coldplate stages
- to reduce SQUID-card temperature. Could probably get wirebonds to superconduct
- may have an impact on base temperature. May need to heat the Still which would exacerbate this
- Lab and infrastructure
- Leak detector: Pump rebuilt. Need to fill with oil and test it.
- Transferring old raw data from /cdms1 to Google shared drive. Have moved 4.6 TB so far.
- PuBe source: plan is to take over the source on our permit, house it in PAN443b, the right cleanroom. We've been storing it in the steel box there with lead, now we will use the “howitzer”.
- Sten returned DCRC55(1) a while ago. We're currently using it. We should ask him again some time if he can diagnose some of the DCRC glitches.
- Future 150mm runs
- 150mm w/phonons - need to design 600mK rod to accommodate 150mm cans
- Received 4/3-inch DIBs from TAMU - now we can house either detector for phonon readout (would need to machine faces on 4/3-inch housing for DIBs)
- S1501 and S1502 sent back to TAMU
- We have decided we can run 8 phonon channels
- Preferred DIB-pad layout: two DIBs separated by 120 degrees
- Himangshu's mask design: PDF download
- Will use existing vacuum-interface electrode, mounted on side opposite the phonon side
- Will connect directly to two DCRCs, with one diverter board to route one tower wire to HV connection
- We'll want LEDs - are there some mounted on the DIBs? We can mount external LEDs too - existing electrode has mounts.
- First 150mm phonon detector will be monolithic, but “donut+hole” arrangement (active veto) proposed as well.
- Aiming for May to finish fabrication and start run.
- Other future runs
- Future HVeV runs?
- Berkeley can help us with a Soudan-style housing mount (3“ or 4”?)
- then use original tower, can try different heatsinking for colder SQUID card
- would need to install optical fiber
- through top or through stripline tube? need vacuum feedthrough
- Look at Prisca's deuterium lamp/monochromator/filters, glass UV fiber
- Is PuBe NR calibration feasible?
- 1×1×0.4 cm^3 is 630× smaller than SNOLAB detector. Anthony estimates 25 events/day (over full spectrum) for Si, 250 events/day for Ge. any chance we could get multiple chips?
- Nick's idea: sandwich between two 4“ Ge detectors for gamma coincidence (large solid angle coverage)
- Other ideas:
- run SiHV with Nick's movable Am source (or with multiple Am sources)
- run SiHV with no 4K heatsinking
- re-run USD1? do we have any additional ideas to test it?
- anything else?