| | The table above shows calculations from IbIs showing how much the dP/dI varies with QET bias near the operating point. I'll use these to try data at a different dP/dI. |
| 2030 | The Goldman thermometer is not plugged in so I don't know the tower temperature. We'll assume it's 40.4 mK like it was before the transfer started. |
| 2040 | Reset QET biases to target dP/dI = 0.9 uV (rather than previous 1.0 uV). Adjust driver offset so set baselines near -0.9 V. |
| 2047 | Dial HV up to 113.3 V using RootSequencer for prebias |
| 2053 | After 5 minutes dial HV down to 98.5 V |
| 2057 | Start 98.6 V data series after 5 min 15% prebias, 42 min long, with 1000 initial randoms, no in-run randoms, trigger on DCRC3pB threshold 10.
Start series with the Start Button. |
| | Bias varied from 98.54 to 98.64 V during series, mostly trending upwards. |
| 2140 | Dial HV down to 0V after data series ends |