UMN CDMS Wiki archive
start › cdms › k100 › run_diary › 20161213

2016/12/13 (Tuesday)

Previous Day

Setup: DIB1/3/4 → 3.2 MHz filters → cables 1,2,3 → HV board inputs 1,3,2 → HV board outputs 1,2 → DCRC55(1)/50(3)
0845 Main bath = 37.2%
0850 This morning all channels look OK at their standard QET biases except DCRC3pC, at 165 uA it seems unstable, but at 166 uA it's ok.
0905 Finish microIbIs measurement at 0V. Vbias values are lower than yesterday morning at 0V by 45 mV on average, range 0-88 mV
1054 Dial HV up to 115 V for prebiasing. Over 5 minutes Vtest falls from around 50 mV to around 25 mV. Breakdown noise evident but pulses still present.
1101 Dial HV down to 100 V
A lot of breakdown noise. Pulses look ok in all channels except DCRC3pC.
1105 Zap SQUIDs
1110 Pulse shapes look much better after zap. All channels operating well at standard QET biases (DCRC1pA/B/C/DCRC3pC/D = 182/185/185/165/202 uA).
DCRC3pC looks like maybe the least noisy channel, will trigger on that one
1120 HV = 100.0 V, Vtest = 12.5 V
1122 Start a sequence 1-hour series of 100V data with Frontend Gain = 5, OG = 2, DCRC3pB intentionally railed, with 1000 beginning randoms, with no flashing in between series, and a 10ADC bin threshold trigger on DCRC3 pC.
1130 Threshold seems too low, adjust DCRC3pC threshold from 10 to 15 ADCbins
1139 Threshold seems too low, adjust DCRC3pC threshold from 15 to 18 ADCbins
1153 Threshold OK but maybe a little higher would be better, adjust DCRC3pC threshold from 18 to 20 ADCbins
1200 Tower/MC/Coldplate = 33.1/36.0/200 mK, Still = 1.04 K / 110 μbar, G1/G2 = 191/171 mbar, 1K Pot = 1.68 K / 22 mbar. MB = 32.2%. Boil off rate: slow mode!
1417 Stop data
1420 Start LHe transfer (27.7%)
1435 Finish microIbIs at 100V. Vbias values are on average 163 mV higher than at 0V this morning, range 57-224 mV
1435 HV = 100.0 V, Vtest = 11.5 V
1440 Dial HV down to 0V
1445 Vtest was around -70 mV after dial-down, has been decreasing, now down to -5 mV and still falling slowly
1500 Finish LHe transfer (92.0%)
1500 Finish microIbIs measurement at 0V. Some of the Vbias values are higher, some lower than at 0V this morning, range from 23 mV higher to -47 mV lower
1505 All channels are back at their standard QET biases and showing pulses. Driver gains are at 2x, probably would want to increase to 8x for any 0V data taking
1545 Flash detector for 30 s
1602 Release MB pressure.
1702 Fill LN2 cold trap full.
1730 Bring out 22Na source.
2018 Set up 22Na coincident trigger, want to run tomorrow from morning till 1pm when the PuBe source comes
2109 just after zap script DCRC2 seemed to spontaneously turn back to RevC.1
2125 Start 60V HV sequence of 10 1-hour series data with 75V, 5min prebias x2 driver gain, Triggering externally on NaI detector with 22Na source, hoping to see coincidences.

Next Day