| JN-3 A, B, C | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2018/08/02 | 1546 | JN | 65.0 | 61.6 | Samples A(THMD 0.2%), B(I-Pr 0.2%), and C(I-Pr 0.4%) placed in water bath |
| 2018/08/03 | 0949 | JN | 65.0 | 61.0 | Refilled Reservoir |
| 2018/08/03 | 1627 | JN | 65.0 | 61.1 | Refilled Reservoir |
| 2018/08/04 | 1407 | JN | 65.0 | 59,9 | Refilled Reservoir |
| 2018/08/05 | 1032 | JN | 65.0 | 60.3 | Refilled Reservoir |
| 2018/08/06 | 0954 | JN | 65.0 | 61.7 | Refilled Reservoir |
| 2018/08/06 | 1634 | JN | 65.0 | 61.7 | Refilled Reservoir |
| 2018/08/07 | 1012 | JN | 65.0 | 60.8 | Refilled Reservoir |
| 2018/08/08 | 1132 | JN | 65.0 | 59.9 | Refilled Reservoir |
| 2018/08/08 | 2114 | JN | 65.0 | 60.6 | Refilled Reservoir |
| JN-2 A, B | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2018/07/16 | 1410 | JN | 65.0 | 61.6 | Samples A(0.3%) and B(0.4%) placed in water bath |
| 2018/07/17 | 0731 | JN | 65.0 | 61.2 | Refilled resevoir |
| 2018/07/17 | 1101 | JN | 65.0 | 61.3 | Refilled resevoir |
| 2018/07/18 | 0938 | JN | 65.0 | 61.0 | Refilled resevoir |
| 2018/07/18 | 1116 | JN | 65.0 | 61.1 | Refilled resevoir |
| 2018/07/19 | 0904 | JN | 65.0 | 60.8 | Refilled resevoir |
| 2018/07/19 | 1619 | JN | 65.0 | 61.1 | Refilled resevoir |
| 2018/07/20 | 1015 | JN | 65.0 | 61.2 | Refilled resevoir |
| 2018/07/20 | 1437 | JN | 65.0 | 61.2 | Refilled resevoir |
| 2018/07/21 | 0907 | PC | 65.0 | 60.8 | Refilled Reservoir |
| 2018/07/21 | 1400 | PC | 65.0 | 61.3 | Refilled reservoir |
| 2018/07/22 | 1200 | PC | 65.0 | 61.2 | Refilled reservoir |
| 2018/07/23 | 0900 | PC | 65.0 | 61.2 | Refilled reservoir |
| 2018/07/23 | 0913 | JN | 65.0 | 61.0 | Began cooldown at rate of 1C every 10min |
| 2018/07/23 | 0928 | JN | 64.0 | 60.6 | Set new reservoir temp |
| 2018/07/23 | 0938 | JN | 63.0 | 60.0 | Set new reservoir temp |
| 2018/07/23 | 0948 | JN | 62.0 | 59.5 | Set new reservoir temp |
| 2018/07/23 | 0959 | JN | 61.0 | 58.5 | Set new reservoir temp |
| 2018/07/23 | 1008 | JN | 60.0 | 57.8 | Set new resevoir temp |
| 2018/07/23 | 1018 | JN | 59.0 | 56.8 | Set new reservoir temp |
| 2018/07/23 | 1028 | JN | 58.0 | 56.1 | Set new reservoir temp |
| 2018/07/23 | 1038 | JN | 57.0 | 55.3 | Set new reservoir temp |
| 2018/07/23 | 1047 | JN | 56.0 | 54.4 | Set new reservoir temp |
| 2018/07/23 | 1058 | JN | 55.0 | 53.3 | Set new reservoir temp |
| JN-1 | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2018/07/10 | 1535 | JN | 65.0 | 61.6 | 1 sample placed in large water bath |
| 2018/07/10 | 2327 | JN | 65.0 | 61.4 | Refilled Resevoir |
| 2018/07/11 | 0905 | JN | 65.0 | 61.4 | Refilled Resevoir |
| 2018/07/11 | 1541 | JN | 65.0 | 61.1 | Refilled Resevoir |
| 2018/07/11 | 2252 | JN | 65.0 | 61.3 | Refilled Resevoir |
| 2018/07/12 | 1005 | JN | 65.0 | 61.4 | Refilled Resevoir |
| 2018/07/12 | 1537 | JN | 65.0 | 61.4 | Refilled Reservoir |
| 2018/07/13 | 0924 | JN | 65.0 | 61.3 | Refilled Reservoir |
| 2018/07/13 | 1823 | JN | 65.0 | 61.5 | Refilled Reservoir |
| 2018/07/14 | 0914 | JN | 65.0 | 61.1 | Begin cool down at rate of 1C every 10min |
| 2018/07/14 | 0924 | JN | 64.0 | 60.9 | Set new reservoir temp |
| 2018/07/14 | 0934 | JN | 63.0 | 60.3 | Set new reservoir temp |
| 2018/07/14 | 0944 | JN | 62.0 | 59.5 | Set new reservoir temp |
| 2018/07/14 | 0954 | JN | 61.0 | 58.7 | Set new reservoir temp |
| 2018/07/14 | 1004 | JN | 60.0 | 57.7 | Set new reservoir temp |
| 2918/07/14 | 1013 | JN | 59.0 | 57.0 | Set new reservoir temp |
| 2018/07/14 | 1023 | JN | 58.0 | 56.2 | Set new reservoir temp |
| 2018/07/14 | 1033 | JN | 57.0 | 55.2 | Set new reservoir temp |
| 2018/07/14 | 1043 | JN | 56.0 | 54.3 | Set new reservoir temp |
| 2018/07/14 | 1053 | JN | 55.0 | 53.5 | Set new reservoir temp |
| 2018/07/14 | 1058 | JN | 54.0 | 53.0 | Set new reservoir temp |
| 2018/07/14 | 1103 | JN | 53.0 | 52.5 | Set new reservoir temp |
| 2018/07/14 | 1108 | JN | 52.0 | 51.9 | Set new reservoir temp |
| 2018/07/14 | 1118 | JN | 50.0 | 50.4 | Set new reservoir temp |
| 2018/07/14 | 1128 | JN | 47.0 | 48.0 | Set ne reservoir temp |
| 2018/07/14 | 1138 | JN | 44.0 | 45.1 | Sample removed from bath |
| S-20 A, B, C, D | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2018/06/05 | 1649 | DMP | 65.0 | 60.3 | Batch of 4 samples placed in large water bath |
| 2018/06/05 | 2237 | DMP | 65.0 | 60.8 | Refilled reservoir. |
| 2018/06/06 | 0803 | JN | 65.0 | 60.8 | Refilled reservoir. |
| 2018/06/06 | 1603 | DMP | 65.0 | 60.7 | Refilled reservoir. |
| 2018/06/06 | 2159 | TA | 65.0 | 61.2 (after refilling. Was similar to above temperatures before refilling) | Refilled Reservoir |
| 2018/06/07 | 0910 | JN | 65.0 | 61.1 | Refilled reservoir |
| 2018/06/07 | 2206 | TA | 65.0 | 60.8 | Refilled Reservoir |
| 2018/06/08 | 1002 | DMP | 65.0 | 60.7 | Refilled reservoir. |
| 2018/06/09 | 1007 | JN | 65.0 | 60.6 | Refilled reservoir |
| 2018/06/09 | 2232 | TA | 65.0 | 60.7 | Refilled reservoir |
| 2018/06/10 | 1411 | JN | 65.0 | 60.9 | Refilled reservoir |
| 2018/06/10 | 2054 | TA | 65.0 | 60.6 | Refilled reservoir . |
| 2018/06/11 | 1028 | JN | 65.0 | 61.0 | Refilled reservoir |
| 2018/06/11 | 1205 | DMP | 64.0 | 60.3 | Started cooldown at rate of about 1C every 10 min. |
| 2018/06/11 | 1218 | DMP | 63.0 | 60.1 | Set new reservoir temp. |
| 2018/06/11 | 1227 | JN | 62.0 | 59.7 | Set new reservoir temp |
| 2018/06/11 | 1237 | JN | 61.0 | 58.9 | Set new reservoir temp |
| 2018/06/11 | 1247 | JN | 60.0 | 58.3 | Set new reservoir temp |
| 2018/06/11 | 1257 | JN | 59.0 | 57.4 | Set new reservoir temp |
| 2018/06/11 | 1307 | JN | 58.0 | 56.6 | Set new reservoir temp |
| 2018/06/11 | 1317 | JN | 57.0 | 55.7 | Set new reservoir temp |
| 2018/06/11 | 1327 | JN | 56.0 | 55.0 | Set new reservoir temp |
| 2018/06/11 | 1337 | JN | 55.0 | 54.0 | Set new reservoir temp |
| 2018/06/11 | 1356 | TA | 54.0 | 52.6 | Set new reservoir temp |
| 2018/06/11 | 1407 | DMP | 53.0 | 51.9 | Set new reservoir temp |
| 2018/06/11 | 1424 | DMP | 52.0 | 50.8 | Set new reservoir temp. |
| 2018/06/11 | 1446 | DMP | 50.0 | 49.8 | Set new reservoir temp. |
| 2018/06/11 | 1459 | DMP | 49.0 | 48.6 | Set new reservoir temp. |
| 2018/06/11 | 1508 | DMP | 48.0 | 47.7 | Set new reservoir temp. |
| 2018/06/11 | 1520 | DMP | 47.0 | 46.7 | Set new reservoir temp. |
| 2018/06/11 | 1538 | TA | 46.0 | 45.6 | Set new reservoir temp. |
| 2018/06/11 | 1548 | TA | 45.0 | 44.6 | Set new reservoir temp. |
| 2018/06/11 | 1600 | DMP | 44.0 | 43.5 | Set new reservoir temp. |
| 2018/06/11 | 1613 | DMP | 43.0 | 42.9 | Set new reservoir temp. |
| 2018/06/11 | 1616 | DMP | 43.0 | 42.5 | Sample A removed from bath. |
| 2018/06/11 | 1637 | DMP | 41.0 | 41.6 | Set new reservoir temp. |
| 2018/06/11 | 1652 | DMP | 39.0 | 40.3 | Set new reservoir temp. |
| 2018/06/11 | 1703 | DMP | 37.0 | 39.0 | Set new reservoir temp. |
| 2018/06/11 | 1715 | DMP | 37.0 | 36.3 | Samples B,C,D removed from bath. |
| DMR-17 A,B,C,D | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2017/07/10 | 1913 | DMP | 62.5 | 57.6 | Batch of 8 samples placed in large water bath |
| DMR-16 A,B,C,D,E,F,G | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| DMR-15 A,B,C,D,E,F,G,H | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Bath Temp (ºC) | Notes |
| 2017/06/10 | 1913 | DMP | 62.5 | 57.6 | Batch of 8 samples placed in large water bath |
| 2017/06/10 | 1940 | DMP | 62.5 | 57.6 | DMR-15B shattered 30 seconds after it was placed in the bath. Shattering was caused by poor design of fiber holder. As styrene leaked throughout the bath and reservoir, all water was drained and replaced. Remaining 7 samples placed in bath. |
| 2017/06/11 | 1113 | DMP | 62.0 | 59.1 | Refilled reservoir. Reservoir dropped from high line to mid point in about 12 hours. |
| 2017/06/12 | 0033 | DMP | 61.5 | 58.5 | Refilled reservoir. |
| 2017/06/12 | 1347 | DMP | 61.5 | 58.1 | Refilled reservoir. |
| 2017/06/12 | 1715 | DMP | 61.5 | 58.1 | Refilled reservoir. |
| 2017/06/13 | 1001 | DMP | 61.5 | 58.1 | Refilled reservoir. |
| 2017/06/13 | 2240 | DMP | 61.5 | 58.1 | Refilled reservoir. |
| 2017/06/14 | 1055 | DMP | 57.5 | 58.1 | Started cooldown at rate of about 2.5C every 30 min. |
| 2017/06/14 | 1200 | DMP | 55.0 | 54.6 | Set new reservoir temp. |
| 2017/06/14 | 1230 | DMP | 52.5 | 52.7 | Set new reservoir temp. |
| 2017/06/14 | 1300 | DMP | 50.0 | 50.7 | Set new reservoir temp. |
| 2017/06/14 | 1340 | DMP | 47.5 | 48.1 | Set new reservoir temp. |
| 2017/06/14 | 1405 | DMP | 45.0 | 46.1 | Set new reservoir temp. |
| 2017/06/14 | 1430 | DMP | 42.5 | 44.1 | Set new reservoir temp. |
| 2017/06/14 | 1500 | DMP | 40.0 | 41.4 | Set new reservoir temp. |
| 2017/06/14 | 1532 | DMP | 37.5 | 39.2 | Set new reservoir temp. |
| 2017/06/14 | 1600 | DMP | 35.0 | 37.0 | Set new reservoir temp. Sample A shattered and was removed from the bath. |
| 2017/06/14 | 1630 | DMP | 32.5 | 34.6 | Set new reservoir temp. Sample H removed from bath to ensure it didn't shatter and contaminated the bath as it was still a viscous liquid. |
| 2017/06/14 | 1644 | DMP | 32.5 | 32.7 | Samples C and F cracked. All samples removed from bath |
| Attempt 18 (DMR-12A,B,C,D): Gd 0%, unloaded long sample | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/12/04 | 2200 | DMP | 62.0 | 57.4 | Batch of 4 samples (A,B,C,D) placed in bath |
| 2016/12/05 | 0957 | DMP | 62.0 | 57.1 | Refilled reservoir |
| 2016/12/05 | 1700 | DMP | 62.0 | 57.4 | Refilled reservoir |
| 2016/12/06 | 0900 | DMP | 62.0 | 58.2 | Refilled reservoir |
| 2016/12/06 | 1600 | DMP | 62.0 | 57.8 | Refilled reservoir |
| 2016/12/06 | 2100 | DMP | 62.0 | 58.2 | Refilled reservoir |
| 2016/12/07 | 0915 | DMP | 62.0 | 57.7 | Refilled reservoir |
| 2016/12/07 | 1600 | DMP | 62.0 | 58.2 | Refilled reservoir |
| 2016/12/07 | 2300 | DMP | 62.0 | 57.8 | Refilled reservoir |
| 2016/12/08 | 0915 | DMP | 62.0 | 57.2 | Refilled reservoir |
| 2016/12/08 | 1215 | DMP | 62.0 | 58.0 | Set reservoir temp to 60.0C |
| 2016/12/08 | 1230 | DMP | 60.0 | 55.4 | Set reservoir temp to 57.5C |
| 2016/12/08 | 1245 | DMP | 57.5 | 52.0 | Set reservoir temp to 55.0C |
| 2016/12/08 | 1300 | DMP | 55.0 | 49.7 | Set reservoir temp to 52.5C |
| 2016/12/08 | 1315 | DMP | 52.5 | 48.0 | Set reservoir temp to 50.0C |
| 2016/12/08 | 1330 | DMP | 50.0 | 46.6 | Set reservoir temp to 47.5C, bottom of vial of DMR12-A came off, sample removed from bath |
| 2016/12/08 | 1345 | DMP | 47.5 | 44.3 | Cool down stopped. All samples removed from bath. Samples appear slightly more yellow than previous samples. Samples decently shorter than the volume of scintillator originally added. Plastic is more brittle than previous samples. |
| Attempt 17 (DMR-10A,B,C,D): Gd 0% (first long samples) | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/08/17 | 1620 | DMP | 60.0 | 57.4 | Batch of 4 samples (A,B,C,D) placed in bath |
| 2016/08/18 | 0957 | RTS | 60.0 | 58.1 | Refilled reservoir |
| 2016/08/19 | 1045 | DMP | 60.0 | 57.4 | Refilled reservoir |
| 2016/08/22 | 1050 | RTS | 60.0 | 58.2 | Refilled reservoir |
| 2016/08/22 | 1411 | RTS | 60.0 | 58.0 | Set reservoir temp to 57.5C |
| 2016/08/22 | 1433 | RTS | 57.5 | 55.6 | Set reservoir temp to 55.0C |
| 2016/08/22 | 1451 | RTS | 55.0 | 53.3 | Set reservoir temp to 52.5C |
| 2016/08/22 | 1508 | RTS | 52.5 | 50.9 | Set reservoir temp to 50.0C |
| 2016/08/22 | 1524 | RTS | 50.0 | 48.5 | Set reservoir temp to 47.5C |
| 2016/08/22 | 1532 | RTS | 47.5 | 46.0 | Vial D cracked; sample removed |
| 2016/08/22 | 1540 | RTS | 47.5 | 46.1 | Set reservoir temp to 45.0C |
| 2016/08/22 | 1555 | RTS | 45.0 | 43.7 | Set reservoir temp to 42.5C |
| 2016/08/22 | 1608 | RTS | 42.5 | 41.3 | Vial B cracked; sample removed |
| 2016/08/22 | 1610 | RTS | 42.5 | 41.3 | Set reservoir temp to 40.0C |
| 2016/08/22 | 1612 | RTS | 40.0 | 38.8 | Vials A and C cracked; samples removed, cooldown stopped |
| Attempt 16 (DMR-09): Gd 0.15% (Gd-TIP #4); small amount of precipitate filtered out | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/06/16 | 1348 | DMP | 60.0 | 58.8 | Moved vial into bath |
| 2016/06/17 | 1050 | RTS | 60.0 | 57.6 | Refilled reservoir |
| 2016/06/17 | 1616 | RTS | 60.0 | 57.3 | Refilled reservoir |
| 2016/06/18 | 1435 | DMP | 60.0 | 58.6 | Refilled reservoir |
| 2016/06/19 | 1516 | DMP | When I arrived, bath was close to low line. Vial in bath had shattered completely. Sample removed and bath turned off. It appeared to be fully polymerized, although a very small defect was present at the top of the sample. | ||
| Attempt 15 (DMR-08): Gd 0.2% (Gd-TIP #4); small amount of precipitate filtered out | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/06/03 | 1243 | DMP | 60.0 | 58.4 | Moved vial into bath |
| 2016/06/06 | 0815 | RTS | 60.0 | 22.2 | Noticed water had stopped circulating, water levels in bath were dangerously low (almost empty), with no water circulating. Refilled tank back to adequate water level. |
| Water bath was not refilled, sample was removed, fully polymerized. However, sample should not be used in any tests. | |||||
| Attempt 14 (DMR-07): Gd 0.05% (Gd-TIP #4); small amount of precipitate filtered out | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/05/25 | 1632 | DMP | 60.0 | 58.8 | Moved vial into bath |
| 2016/05/26 | 1217 | DMP | 60.0 | 58.7 | Refilled reservoir |
| 2016/05/27 | 1238 | DMP | 60.0 | 58.6 | Refilled reservoir |
| 2016/05/27 | 2255 | DMP | 60.0 | 58.5 | Refilled reservoir |
| 2016/05/29 | 0016 | DMP | 60.0 | 58.7 | Refilled reservoir |
| 2016/05/29 | 1700 | DMP | 60.0 | 58.8 | Started cool down @ 2.5C every 15 min |
| 2016/05/29 | 1715 | DMP | 57.5 | 56.2 | Set reservoir temp to 55.0C |
| 2016/05/29 | 1730 | DMP | 55.0 | 53.8 | Set reservoir temp to 52.5C |
| 2016/05/29 | 1745 | DMP | 52.5 | 51.3 | Set reservoir temp to 50.0C |
| 2016/05/29 | 1800 | DMP | 50.0 | 48.9 | Set reservoir temp to 47.5C |
| 2016/05/29 | 1815 | DMP | 47.5 | 46.4 | Set reservoir temp to 45.0C |
| 2016/05/29 | 1830 | DMP | 45.0 | 44.1 | Set reservoir temp to 42.5C |
| 2016/05/29 | 1845 | DMP | 42.5 | 41.7 | Set reservoir temp to 40.0C |
| 2016/05/29 | 1900 | DMP | 40.0 | 39.3 | Set reservoir temp to 37.5C |
| 2016/05/29 | 1915 | DMP | 37.5 | 36.9 | Set reservoir temp to 35.0C |
| 2016/05/29 | 1923 | DMP | 35.0 | 34.3 | vial shattered, sample removed |
| Attempt 13 (DMR-06): Gd 0.1% (Gd-TIP #4); small amount of precipitate filtered out | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 2016/05/04 | 1948 | RTS | 60.0 | 58.8 | Moved vial into bath |
| 2016/05/05 | 1132 | DMP | 60.0 | 58.8 | Refilled reservoir |
| 2016/05/06 | 1149 | DMP | 60.0 | 58.6 | Refilled reservoir |
| 2016/05/07 | 1240 | RTS | 60.0 | 58.5 | Set reservoir temp to 57.5C |
| 2016/05/07 | 1255 | RTS | 57.5 | 56.0 | Set reservoir temp to 55.0C |
| 2016/05/07 | 1310 | RTS | 55.0 | 53.6 | Set reservoir temp to 52.5C |
| 2016/05/07 | 1325 | RTS | 52.5 | 51.2 | Set reservoir temp to 50.0C |
| 2016/05/07 | 1340 | RTS | 50.0 | 48.8 | Set reservoir temp to 47.5C |
| 2016/05/07 | 1410 | RTS | 47.5 | 46.4 | Set reservoir temp to 45.0C |
| 2016/05/07 | 1425 | RTS | 45.0 | 44.0 | Set reservoir temp to 42.5C |
| 2016/05/07 | 1440 | RTS | 42.5 | 41.7 | Set reservoir temp to 40.0C |
| 2016/05/07 | 1455 | RTS | 40.0 | 39.3 | Set reservoir temp to 37.5C |
| 2016/05/07 | 1510 | RTS | 37.5 | 36.8 | Set reservoir temp to 35.0C |
| 2016/05/07 | 1525 | RTS | 35.0 | 32.5 | Set reservoir temp to 32.5C |
| 2016/05/07 | 1540 | RTS | 32.5 | 32.1 | Set reservoir temp to 30.0C |
| 2016/05/07 | 1600 | RTS | 30.0 | 29.5 | Vial removed, bottom of vial separated from rest, otherwise intact |
| Attempt 12: Gd 0.1% (new, Gd-tris(isopropoxide)) | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 17/02/2016 | 1910 | DMP | 62.5 | 60.8 | Moved vial into bath |
| 18/02/2016 | 1023 | DMP | 60.0 | 58.7 | Refilled reservoir |
| 18/02/2016 | 1722 | DMP | 60.0 | 58.5 | Refilled reservoir |
| 19/02/2016 | 1201 | DMP | 60.0 | 58.2 | Refilled reservoir |
| 19/02/2016 | 1635 | DMP | 60.0 | 58.1 | Refilled reservoir |
| 20/02/2016 | 1135 | DMP | 60.0 | 58.1 | Refilled reservoir |
| 21/02/2016 | 1200 | DMP | 60.0 | 58.3 | Set reservoir temp to 57.5C |
| 21/02/2016 | 1215 | DMP | 57.5 | 55.9 | Set reservoir temp to 55.0C |
| 21/02/2016 | 1230 | DMP | 55.0 | 53.5 | Set reservoir temp to 52.5C |
| 21/02/2016 | 1245 | DMP | 52.5 | 51.1 | Set reservoir temp to 50.0C |
| 21/02/2016 | 1300 | DMP | 50.0 | 48.7 | Set reservoir temp to 47.5C |
| 21/02/2016 | 1315 | DMP | 47.5 | 46.3 | Set reservoir temp to 45.0C |
| 21/02/2016 | 1330 | DMP | 45.0 | 43.9 | Set reservoir temp to 42.5C |
| 21/02/2016 | 1345 | DMP | 42.5 | 41.4 | Set reservoir temp to 40.0C |
| 21/02/2016 | 1353 | DMP | 40.0 | 39.1 | vial cracked |
| 21/02/2016 | 1400 | DMP | 40.0 | 39.1 | Set reservoir temp to 37.5C |
| 21/02/2016 | 1415 | DMP | 37.5 | 36.6 | Set reservoir temp to 35.0C |
| 21/02/2016 | 1430 | DMP | 35.0 | 34.2 | Cooldown stopped, vial removed |
| Attempt 11: Gd 0.05% (new, Gd-tris(isopropoxide)) | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 17/02/2016 | 1910 | DMP | 60.0 | 60.8 | Moved vial into bath |
| 18/02/2016 | 1023 | DMP | 60.0 | 58.7 | Refilled reservoir |
| 18/02/2016 | 1722 | DMP | 60.0 | 58.5 | Refilled reservoir |
| 19/02/2016 | 1201 | DMP | 60.0 | 58.2 | Refilled reservoir |
| 19/02/2016 | 1635 | DMP | 60.0 | 58.1 | Refilled reservoir |
| 20/02/2016 | 1135 | DMP | 60.0 | 58.1 | Refilled reservoir |
| 21/02/2016 | 1200 | DMP | 60.0 | 58.3 | Set reservoir temp to 57.5C |
| 21/02/2016 | 1215 | DMP | 57.5 | 55.9 | Set reservoir temp to 55.0C |
| 21/02/2016 | 1230 | DMP | 55.0 | 53.5 | Set reservoir temp to 52.5C |
| 21/02/2016 | 1245 | DMP | 52.5 | 51.1 | Set reservoir temp to 50.0C |
| 21/02/2016 | 1300 | DMP | 50.0 | 48.7 | Set reservoir temp to 47.5C |
| 21/02/2016 | 1315 | DMP | 47.5 | 46.3 | Set reservoir temp to 45.0C |
| 21/02/2016 | 1330 | DMP | 45.0 | 43.9 | Set reservoir temp to 42.5C |
| 21/02/2016 | 1345 | DMP | 42.5 | 41.4 | Set reservoir temp to 40.0C |
| 21/02/2016 | 1400 | DMP | 40.0 | 39.1 | Set reservoir temp to 37.5C |
| 21/02/2016 | 1415 | DMP | 37.5 | 36.6 | Set reservoir temp to 35.0C |
| 21/02/2016 | 1430 | DMP | 35.0 | 34.2 | Cooldown stopped, vial removed, vial fully intact |
| Attempt 10: Gd 0.1% (new, Gd-tris(isopropoxide)) | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 10/02/2016 | 1808 | DMP | 62.5 | 60.8 | Moved vial into bath |
| 11/02/2016 | 1238 | DMP | 62.5 | 60.9 | Refilled reservoir |
| 11/02/2016 | 1823 | RTS | 62.5 | 60.7 | Refilled reservoir |
| 12/02/2016 | 1115 | DMP | 62.5 | 60.9 | Refilled reservoir |
| 12/02/2016 | 1241 | RTS | 62.5 | 60.5 | Refilled reservoir |
| 12/02/2016 | 1558 | RTS | 62.5 | 60.3 | Refilled reservoir |
| 12/02/2016 | 2051 | DMP | 62.5 | 60.6 | Refilled reservoir |
| 13/02/2016 | 1145 | RTS | 62.5 | 61.1 | Started cool down @ 2.5C every 15 min |
| 13/02/2016 | 1200 | RTS | 60.0 | 58.3 | Set reservoir temp to 57.5C |
| 13/02/2016 | 1215 | RTS | 57.5 | 55.9 | Set reservoir temp to 55.0C |
| 13/02/2016 | 1230 | RTS | 55.0 | 53.5 | Set reservoir temp to 52.5C |
| 13/02/2016 | 1245 | RTS | 52.5 | 51.1 | Set reservoir temp to 50.0C |
| 13/02/2016 | 1300 | RTS | 50.0 | 48.7 | Set reservoir temp to 47.5C |
| 13/02/2016 | 1315 | RTS | 47.5 | 46.3 | Set reservoir temp to 45.0C |
| 13/02/2016 | 1330 | RTS | 45.0 | 43.9 | Set reservoir temp to 42.5C |
| 13/02/2016 | 1345 | RTS | 42.5 | 41.4 | Set reservoir temp to 40.0C |
| 13/02/2016 | 1400 | RTS | 40.0 | 39.1 | Set reservoir temp to 37.5C |
| 13/02/2016 | 1415 | RTS | 37.5 | 36.6 | Set reservoir temp to 35.0C |
| 13/02/2016 | 1430 | RTS | 35.0 | 34.2 | Set reservoir temp to 32.5C |
| 13/02/2016 | 1438 | RTS | 32.5 | 31.7 | vial shattered, removed sample |
| Attempt 9: Gd .1% (old, Gd-tris(isopropoxide)) | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 03/02/2016 | 1823 | RTS | 62.5 | 59.6 | Moved vial into bath |
| 03/02/2016 | 1900 | RTS | 62.5 | 60.0 | Refilled reservoir |
| 04/02/2016 | 0849 | DMP | 62.5 | 60.2 | Refilled reservoir |
| 04/02/2016 | 1826 | RTS | 62.5 | 60.7 | Refilled reservoir |
| 05/02/2016 | 1111 | DMP | 62.5 | 59.9 | Refilled reservoir |
| 06/02/2016 | 1009 | DMP | 62.5 | 58.8 | Refilled reservoir |
| 06/02/2016 | 1047 | DMP | 62.5 | 58.8 | Started cool down @ 2.5C every 15 min |
| 06/02/2016 | 1105 | DMP | 60.0 | 56.6 | Set reservoir temp to 57.5C |
| 06/02/2016 | 1120 | DMP | 57.5 | 54.4 | Set reservoir temp to 55.0C |
| 06/02/2016 | 1135 | DMP | 55.0 | 52.0 | Set reservoir temp to 52.5C |
| 06/02/2016 | 1150 | RTS | 52.5 | 49.8 | Set reservoir temp to 50.0C |
| 06/02/2016 | 1205 | RTS | 50.0 | 47.4 | Set reservoir temp to 47.5C |
| 06/02/2016 | 1220 | RTS | 47.5 | 45.0 | Set reservoir temp to 45.0C |
| 06/02/2016 | 1235 | RTS | 45.0 | 42.7 | Set reservoir temp to 42.5C |
| 06/02/2016 | 1250 | RTS | 42.5 | 40.4 | Set reservoir temp to 40.0C |
| 06/02/2016 | 1305 | DMP | 40.0 | 38.3 | Set reservoir temp to 37.5C |
| 06/02/2016 | 1320 | RTS | 37.5 | 35.9 | Set reservoir temp to 35.0C |
| 06/02/2016 | 1335 | DMP | 35.0 | 33.6 | Set reservoir temp to 32.5C |
| 06/02/2016 | 1341 | DMP | 32.5 | 31.2 | vial shattered, removed sample |
| Attempt 8: Styrene, BPO, PPO, and POPOP added; No Gd | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 27/01/2016 | 1753 | RTS | 60.0 | 59.4 | Moved vial into bath |
| 28/01/2016 | 0846 | DMP | 60.0 | 60.1 | Refilled reservoir |
| 28/01/2016 | 1154 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 28/01/2016 | 1823 | RTS | 60.0 | 59.4 | Refilled reservoir |
| 29/01/2016 | 0946 | DMP | 60.0 | 59.5 | Refilled reservoir |
| 29/01/2016 | 1226 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 29/01/2016 | 1722 | DMP | 60.0 | 59.3 | Refilled reservoir |
| 30/01/2016 | 0854 | DMP | 60.0 | 59.5 | Refilled reservoir |
| 30/01/2016 | 1446 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 30/01/2016 | 1938 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 31/01/2016 | 1011 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 31/01/2016 | 2103 | DMP | 60.0 | 59.4 | Refilled reservoir |
| 01/02/2016 | 0934 | DMP | 60.0 | 59.5 | Refilled reservoir |
| 01/02/2016 | 1645 | DMP | 60.0 | 59.4 | Started cool down @ 2.5C every 15 min |
| 01/02/2016 | 1704 | DMP | 57.5 | 56.9 | Set reservoir temp to 55.0C |
| 01/02/2016 | 1720 | DMP | 55.0 | 54.5 | Set reservoir temp to 52.5C |
| 01/02/2016 | 1735 | DMP | 52.5 | 51.9 | Set reservoir temp to 50.0C |
| 01/02/2016 | 1750 | DMP | 50.0 | 49.5 | Set reservoir temp to 47.5C |
| 01/02/2016 | 1805 | DMP | 47.5 | 47.4 | Set reservoir temp to 45.0C |
| 01/02/2016 | 1820 | DMP | 45.0 | 44.6 | Set reservoir temp to 42.5C |
| 01/02/2016 | 1835 | DMP | 42.5 | 42.1 | Set reservoir temp to 40.0C |
| 01/02/2016 | 1850 | DMP | 40.0 | 39.6 | Set reservoir temp to 37.5C |
| 01/02/2016 | 1905 | DMP | 37.5 | 37.2 | Set reservoir temp to 35.0C |
| 01/02/2016 | 1905 | DMP | 35.0 | 34.5 | Set reservoir temp to 32.5C |
| 01/02/2016 | 1920 | DMP | 32.5 | 32.1 | Set reservoir temp to 30.0C |
| 01/02/2016 | 1935 | DMP | 30.0 | 29.5 | Cool down stopped, vial removed, vial fully intact |
| Attempt 7: 0.1% Gd, filtered after sonicating | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 10/08/2015 | 1451 | SDD | 60.0 | 57.9 | Moved vial into bath |
| 11/08/2015 | 0806 | SDD | 60.0 | 59.1 | Refilled reservoir |
| 11/08/2015 | 1520 | ADM | 60.0 | 58.9 | Refilled reservoir |
| 12/08/2015 | 0804 | SDD | 60.0 | 59.1 | Refilled reservoir |
| 13/08/2015 | 0826 | SDD | 60.0 | 59.1 | Refilled reservoir |
| 14/08/2015 | 1100 | HER | 60.0 | 58.5 | Started cool down with 2.5C per 15 minutes |
| 14/08/2015 | 1200 | HER | 50.0 | 49.3 | cooldown paused |
| 14/08/2015 | 1255 | ADM | 50.0 | 48.9 | cooldown resumed, 5C / 30 min |
| 14/08/2015 | 1519 | ADM | 34.9 | 34.4 | vial shattered, sample removed from bath |
| Attempt 6: 0.1% Gd | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 03/08/2015 | 1425 | SDD | 60.2 | 58.5 | Moved vial into bath |
| 03/08/2015 | 1541 | ADM | 60.0 | 58.0 | refilled bath |
| 04/08/2015 | 0824 | SDD | 60.0 | 58.8 | refilled bath |
| 04/08/2015 | 1311 | ADM | 60.0 | 58.6 | refilled reservoir to high line |
| 05/08/2015 | 0858 | SDD | 60.0 | 58.8 | refilled reservoir |
| 05/08/2015 | 1519 | ADM | 60.0 | 58.6 | refilled reservoir |
| 06/08/2015 | 0835 | SDD | 60.0 | 58.8 | refilled reservoir |
| 06/08/2015 | 1538 | ADM | 60.0 | 58.7 | refilled reservoir to high line |
| 07/08/2015 | 0915 | SDD | 60.0 | 58.5 | started cooldown 1C per ten minutes |
| 07/08/2015 | 1045 | SDD | 50.0 | 48.9 | paused cooldown |
| 07/08/2015 | 1125 | SDD | 50.0 | 48.9 | resumed cooldown |
| Attempt 5: With Gadolinium 1% | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 27/07/2015 | 1521 | SDD | 60.0 | 58.9 | Moved vial into bath. Sample is cloudy |
| 28/07/2015 | 0907 | SDD | 60.0 | 59.1 | refilled reservoir |
| 28/07/2015 | 1604 | ADM | 60.0 | 58.9 | filled reservoir to high line |
| 29/07/2015 | 0926 | SDD | 60.0 | 59.2 | refilled reservoir |
| 29/07/2015 | 1601 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 30/07/2015 | 0906 | SDD | 60.0 | 59.1 | refilled reservoir |
| 30/07/2015 | 1716 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 31/07/2015 | 0910 | SDD | 60.0 | 59.2 | refilled reservoir, balloon is deflated |
| 31/07/2015 | 1015 | SDD | 60.0 | 59.0 | started cooldown 1C per ten minutes |
| 31/07/2015 | 1510 | ADM | 30.0 | 29.6 | sample vial cracked |
| Attempt 4: Slower cooldown | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 06/07/2015 | 1554 | ADM | 60.0 | 58.9 | moved vial into bath |
| 07/07/2015 | 0909 | SDD | 60.0 | 59.2 | refilled reservoir |
| 07/07/2015 | 1437 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 08/07/2015 | 0923 | SDD | 60.0 | 59.1 | refilled reservoir |
| 08/07/2015 | 1517 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 09/07/2015 | 0946 | SDD | 60.0 | 59.1 | refilled reservoir |
| 09/07/2015 | 1659 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 10/07/2015 | 0912 | SDD | 60.0 | 59.0 | refilled reservoir |
| 10/07/2015 | 1000 | SDD | 60.0 | 59.0 | started cooldown 1C per ten minutes |
| 10/07/2015 | 1346 | ADM | 36.7 | 36.3 | sample vial cracked |
| 10/07/2015 | 1355 | ADM | 35.0 | 34.3 | dropped setpoint to 25.0C for fast cooldown |
| 10/07/2015 | 1411 | ADM | 25.3 | 25.2 | turned off recirculator, removed sample |
| Attempt 3: Addition of PPO and POPOP | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 29/06/2015 | 1520 | ADM | 60.0 | 58.9 | moved vial into bath |
| 29/06/2015 | 1623 | ADM | 60.0 | 58.9 | filled reservoir to “high” line |
| 30/06/2015 | 0925 | SDD | 60.0 | 59.1 | refilled reservoir |
| 01/07/2015 | 0907 | SDD | 60.0 | 59.1 | |
| 01/07/2015 | 1357 | ADM | 60.0 | 58.9 | refilled reservoir to “high” line |
| 01/07/2015 | 1605 | SDD | 60.0 | 58.8 | refilled reservoir to “high” line |
| 02/07/2015 | 0908 | SDD | 60.0 | 59.1 | refilled reservoir |
| 02/07/2015 | 1243 | ADM | 60.0 | 58.9 | dropped setpoint to 57.5C |
| 02/07/2015 | 1300 | ADM | 57.5 | 56.5 | dropped setpoint to 55.0C |
| 02/07/2015 | 1315 | ADM | 55.0 | 54.1 | dropped setpoint to 52.5C |
| 02/07/2015 | 1330 | ADM | 52.5 | 51.6 | dropped setpoint to 50.0C |
| 02/07/2015 | 1345 | ADM | 50.0 | 49.2 | dropped setpoint to 47.5C |
| 02/07/2015 | 1400 | ADM | 47.5 | 46.8 | dropped setpoint to 45.0C |
| 02/07/2015 | 1416 | ADM | 45.0 | 44.4 | dropped setpoint to 42.5C |
| 02/07/2015 | 1431 | ADM | 42.5 | 41.9 | dropped setpoint to 40.0C |
| 02/07/2015 | 1435 | ADM | 39.9 | 39.3 | sample vial cracked |
| 02/07/2015 | 1445 | ADM | 40.0 | 39.5 | dropped setpoint to 37.5C |
| 02/07/2015 | 1500 | ADM | 37.5 | 37.0 | dropped setpoint to 35.0C |
| 02/07/2015 | 1515 | ADM | 35.0 | 34.5 | dropped setpoint to 32.5C |
| 02/07/2015 | 1530 | ADM | 32.5 | 32.0 | dropped setpoint to 30.0C |
| 02/07/2015 | 1545 | ADM | 30.0 | 29.6 | dropped setpoint to 27.5C |
| 02/07/2015 | 1600 | ADM | 27.5 | 27.1 | dropped setpoint to 25.0C |
| 02/07/2015 | 1604 | ADM | 24.9 | 24.5 | turned off recirculator |
| Attempt 2: Just styrene and BPO: Too much BPO was added to styrene; this attempt should not fully polymerize, but we can practice the techniques again :/ | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 23/06/2015 | 1209 | HER | 60.0 | 58.9 | reservoir filled to “high” line; sample placed in water bath |
| 23/06/2015 | 1410 | SDD | 60.0 | 59.0 | reservoir water level still at “high” line |
| 23/06/2015 | 1631 | HER | 60.5 | 59.6 | filled reservoir to “high” line |
| 24/06/2015 | 0931 | SDD | 60.0 | 59.1 | refilled reservoir |
| 24/06/2015 | 1530 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 25/06/2015 | 0909 | SDD | 60.0 | 59.0 | refilled reservoir |
| 25/06/2015 | 1532 | SDD | 60.0 | 59.1 | filled reservoir to “high” line |
| 26/06/2015 | 0931 | SDD | 60.0 | 59.1 | refilled reservoir, balloon appears much deflated but still has some pressure, no bubbles visible in the sample |
| 26/06/2015 | 1251 | ADM | 60.0 | 59.0 | started cooldown to room temp, dropped setpoint to 55.0C |
| 26/06/2015 | 1321 | ADM | 55.0 | 54.1 | dropped setpoint to 50.0C |
| 26/06/2015 | 1351 | ADM | 50.0 | 49.2 | dropped setpoint to 45.0C |
| 26/06/2015 | 1403 | ADM | 44.9 | 44.3 | sample vial cracked |
| 26/06/2015 | 1421 | ADM | 45.0 | 44.4 | dropped setpoint to 40.0C |
| 26/06/2015 | 1452 | ADM | 40.0 | 39.5 | dropped setpoint to 35.0C |
| 26/06/2015 | 1521 | ADM | 35.0 | 34.5 | dropped setpoint to 30.0C |
| 26/06/2015 | 1550 | ADM | 30.0 | 29.7 | dropped setpoint to 25.0C |
| 26/06/2015 | 1559 | ADM | 25.0 | 25.0 | turned off recirculator, removed sample vial; sample is completely solid |
| Attempt 1: Just styrene and BPO | |||||
|---|---|---|---|---|---|
| Date | Time | Name | Reservoir Temp (ºC) | Beaker Temp (ºC) | Notes |
| 15/06/2015 | 1632 | HER | 58.0 | 55.3 | Sample placed in beaker at 1619, so bath might still be heating |
| 16/06/2015 | 0845 | ADM | 58.0 | 57.0 | Water level ~ 3/4 full; water added; temperature dropped to 51.4 C(beaker) |
| 16/06/2015 | 1154 | SDD | 58.0 | 51.5 | |
| 16/06/2015 | 1224 | SDD | 59.4 | 53.5 | Reservoir Temp setting adjusted to 59.5 C |
| 16/06/2015 | 1423 | HER | 65.0 | 56.8 | Increased reservoir temp to 65.0 C |
| 17/07/2015 | 0838 | ADM | 65.0 | 56.1 | Water level below “low” line in reservoir, filled halfway to “high” line |
| 17/07/2015 | 0846 | ADM | 60.0 | 58.6 | Opened flow valve slightly to increase water circulation rate – seemed to dramatically decrease temp. difference between reservoir and beaker |
| 17/06/2015 | 1049 | SDD | 60.0 | 58.4 | |
| 17/06/2015 | 1222 | ADM | 60.0 | 58.2 | refilled reservoir |
| 17/06/2015 | 1624 | SDD | 60.0 | 58.3 | filled reservoir to “high” line |
| 18/06/2015 | 0915 | SDD | 60.0 | 58.5 | refilled reservoir |
| 18/06/2015 | 1540 | SDD | 60.0 | 58.6 | filled reservoir to “high” line |
| 19/06/2015 | 0918 | SDD | 60.0 | 58.2 | refilled reservoir halfway to “high” line |