List of Figures/Information for Paper
- Geometry: diameter=2.5cm, length=8cm scintillator sample coupled to PMT
- Figure visualizing geometry: See email (11/10)
- Muons incident at 4cm from sample end
- Value of mean energy deposited with error: 5.339 +/- 0.003 MeV
- 511 keV gammas incident at 4cm from sample end
- Value of mean energy deposited with error 44.1 +/- 0.1 keV
- Geometry: sample with embedded WLS fiber coupled to PMT
- Figure visualizing geometry See email (11/10)
- Value (with error) for WLS fiber capture efficiency (See page 9 of Monte Carlo Writeup (v4), hyperlinked below in the absorption/emission spectra line)
- Above doc contains numbers/figures concerning this parameter; the Monte Carlo upper bound on the way the WLS efficiency was collected is 16%; the figure obtained by experiment is 32%, but after some discussion Prisca, DMP, and I concluded that we might want to reanalyze that original experiment
- Absorption and emission spectra you used for both the plastic scintillator and for WLS fiber
- Note: I am using the “measured” spectra now as opposed to the “simulated” spectra, which is what existed before
- See 11/16 email
- Figure showing geometry of neutron capture efficiency setup
- See email (11/10)
- A list of the physics lists you used in the sim
- G4EmStandardPhysics_option4
- G4EmExtraPhysics
- G4DecayPhysics
- G4RadioactiveDecayPhysics
- G4HadronElasticPhysicsHP
- G4HadronPhysicsShielding
- G4StoppingPhysics
- G4IonQMDPhysics
- G4IonElasticPhysics
- G4OpticalPhysics