Run 76 Data Summary

K100 data spreadsheet: dataserieslist.xlsx

Summary

Configuration Bias Trigger source Radiation source Shield Amount Notes Rows
2-sided 0V SiHV Am only Partial 3.3 hours Data at three different Am source positions
Side2 scan 0V up to -238V SiHV Am only Partial 19 series
Side2 0V SiHV Na-22 Partial 2 series NaI coincidence tests
Side2 0V SiHV, NaI PuBe Complete except borax 2 series Test PuBe paraffin drum at two positions
Side2 0V SiHV, NaI Am only Complete 2 series Muon test. NaI trigger configured for muons.
Side2 -197V NaI PuBe Complete 61 hours NaI window 7.6-11.2 MeV (before recalibration). But probably changed by accident during this dataset.
In July 2022 we started having He-film problems. After this point we started taking data in ~2-day stretches with pumpouts between.
Also after this point the maximum bias on the detector is around -84V due to increased leakage after HV mishap.
Also the NaI amplitudes were recalibrated at this time. NaI trigger windows should be more reliable for data after this point.
Side2 0V to -84V SiHV PuBe Complete 5 series “Ladder calibration” data. 95-99
Side2 -84V NaI PuBe Complete 21 hours NaI window 7.6-11.2 MeV 101-108
Side2 various NaI PuBe Complete 5 biases NaI window 7.6-11.2 MeV 116-128
Side2 -81V NaI PuBe Complete 57 hours NaI window 7.6-11.2 MeV 129-147
Side2 various NaI Am only Complete 4 biases NaI window 7.6-11.2 MeV 148-158
Side2 -83V SiHV Am-only Complete 17 hours Low trigger threshold (R68-style) 159
Side2 -83V SiHV PuBe Complete 69 hours Low trigger threshold (R68-style) 160
Side2 -83V NaI PuBe Complete 41 hours NaI window adjusted (7.6-11.0 MeV) to avoid saturation peak 163-171
Side2 -82V SiHV Am-only Complete 43 hours Low trigger threshold (R68-style) 172-173
Side2 -83V NaI PuBe Complete 41 hours NaI window 7.0-11.0 MeV 174-181
Side2 -82V NaI PuBe Complete 70 hours NaI window 4.73-5.93 MeV (may have been reset by mistake at some point) 192-206
Side2 -82V SiHV PuBe Complete 23 hours Low trigger threshold (R68-style). NaI coincidence data taken too, not sure if we did that with previous R68-style data 211-213
Side2 various lower biases SiHV PuBe Complete 10 biases Low trigger threshold (R68-style). 215-233
Side2 -82V NaI Am only Complete 14 hours NaI window 4.73-5.93, or 4.73-5.13? not sure 234-236

Processing notes

All data has been processed with an initial processing configuration. Calculated templates are used with risetime/falltime chosen empirically to match lowest-amplitude phonon pulses (targeting lowest part of energy spectrum). Default phonon start-time chosen, which does not quite match phonon t0 in the case of NaI-triggered data.