2023/01/19 (Thursday)

Previous Day

  • Lab in-personnel: Zach, HImangshu, Carson
Status Run 77 preparation
Setup DCRC33(2)→HV control, NaI trigger signal → DCRCX(4)
IVC closed and Turbo pumping for a while. No tower - this was just for a leak test.
1205 Check contents of warm LN2 Trap 1: 13.2 mbar. Pump it out with the scroll pump.
1215 G1 = 2.2 mbar and stable, stop pumping on Trap 1
1220 Place cold trap 1 in the LN2 bath, begin filling with LN2.
1230 Begin cryocleaning mixture through cold trap 1
1234 Open V6 to 12.1% to restart flow
1247 Open V6 to 12.4% to restart flow
1345 End cryocleaning, pump mixture to dump.
1402 G1 = 1.9 mbar and stable. Close all valves and turn off 3He pump, leaving 729.6 mbar in dump. Pull out cold trap 1.
1417 Check contents of warm LN2 Trap 2: 1.5 mbar. Pump it out with the scroll pump.
1430 Begin cryocleaning mixture through cold trap 2, V6 at 12.5%.
1536 Open V6 to 12.6% to restart flow
1600 Mount sources (stationary Am pellet and movable Am) on the 2d source mover and assemble tower with the two thermometers (new RX-102B-RS and old U02844) on top
1612 End cryocleaning, pump mixture to dump.
1627 G1 = 1.9 mbar and stable. Close all valves and turn off 3He pump, leaving 731.0 mbar in dump. Pull out cold trap 2
1633 Cold trap 1 should be warm enough now, check contents: 13.2 mbar. Pump it out with the scroll pump.
1700 I put cold trap 1 back into the LN2 bath but decided not to do another cryocleaning cycle.
Run 77 Tower Electrical Checkout
Device Label Unit Value
Face5pA Side1pE Ω 326.3
Face5pB Side1pB Ω 140.4
Face5pC Side1pD Ω 402.7
Face5pD Side2pE Ω 318.8
Face5pA-pB same side inter Ω 493
Face5pA-pC same side inter kΩ 0.681
Face5pA-pD opp side inter kΩ 2.107
Face5pB-pC same side inter Ω 419
Face5pB-pD opp side inter kΩ 1.916
Face5pC-pD opp side inter kΩ 1.87
Face5LED1 pin-to-chassis V 1.068
Face5LED2 pin-to-chassis V 0.868
Face3pA Side2pC Ω old 377.1
Face3pB Side2pF Ω old 516.9
Face3pC Side1pC Ω old 438.7
Face3pD Side1pF Ω old 440.6
Face3pA-pB same side inter kΩ old 1.848
Face3pA-pC opp side inter kΩ old 2.813
Face3pA-pD opp side inter kΩ old 2.776
Face3pB-pC opp side inter kΩ old 2.906
Face3pB-pD opp side inter kΩ old 2.803
Face3pC-pD same side inter kΩ old 1.936
Face2pA Side2pB Ω old 140.8
Face2pB Side2pA Ω old 87.1
Face2pC Side1pA Ω old 101.1
Face2pD Side2pD Ω old 389.7
Face2pA-pB same side inter kΩ old 0.774
Face2pA-pC opp side inter kΩ old 1.992
Face2pA-pD same side inter kΩ old 1.347
Face2pB-pC opp side inter kΩ old 2.121
Face2pB-pD same side inter kΩ old 1.644
Face2pC-pD opp side inter kΩ old 2.395
Face2pA-chassis detector shorts Ω
Face6 1-2 Motor Y 1-2 Ω old 150.1
Face6 3-4 Motor Y 3-4 Ω old 147.3
Face6 6-7 Motor X 1-2 Ω old 145.7
Face6 8-9 Motor X 3-4 Ω old 145.5
Face6 12-13 Piezo, rest mVac old 3
Piezo, tap mVac old 30
1730 We will continue the electrical test tomorrow

Next Day