2018/09/21 (Friday)

Previous Day

Setup:
DIB1/3/4 → 3.2 MHz filters 2/3/1 → cable 3/1/2 → gender changer 3/?/2 → HVConn 1/3/2 → HV 1/2 → DCRC55(1)/DCRC50(3)

1.1kV → NaI B/C → Ortec 452(gain=5, shaping = 6 us, output=10V) / Ortec 575A(gain=10, shaping = 3us) → x10/x10 attenuator → DCRCX(4)
DCRC33(2) → kepco 1kV power supply → HV input
status: Power failure last night, restarted recovery around ~2000. Things look stable overnight, tower = 29.5 mK
0805 Zap SQUIDs. Didn't work, DCRC driver crashed.
0911 Tower/MC/Coldplate = 29.5/30.1/184 mK, Still = 0.0 mW / 1.4±0.1 K / 0.095 mbar, G1/G2 = 132/131 mbar, 1K Pot = 1.60 K / 17 mbar, Turbo on IVC = 0.86 nbar, MB = 70.4%
0915 Can't telnet to DCRC1, power cycle it. Now we cant telnet to all 4 of them.
0917 Fill LN2 cold trap.
0920 Start dcrc_driver01 and zap SQUIDs. Seems to have worked this time.
0930 All channels operating properly.
0938 Start 2 hr, -240 V bkg dataset with 4% prebias (-250V) for 5 min, split into 10 min subruns, with CDMS and NaI detectors running and DCRC2 as HV controller. Using sequence HVscan-240×1-4_5PreBias-DCRC2_250–30Flash-30wait-2hrData-10minSubRun.msl
CDMS detector: Driver Gains = 2x, QET biases = (280/260/305)/(140/280/295) uA, Front-End Gains = (10/10/10)/(10/15/10)
NaI detector: 1.1kV → NaI B/C → Ortec 452(gain=5, shaping = 6 us, output=10V, Neg) / Ortec 575A(gain=10, shaping = 3us, Neg) → x10/x10 attenuator → DCRC4PB/PA, Driver Gains = 1/1, PhononWaveFormLength = 1024 (512 samples), PhononPrepulseSamples = 64 (64 samples)
1000 BOR randoms, trigger on DCRC3pB/C/D threshold = 7/10/9
1120 DCRC3pC has been railed low the whole time, fix it.
1225 Remove 22Na source from safe and place inside lead/poly shield at bottom of NW corner.
1232 Start 1 hr, -240 V 22Na dataset with 4% prebias (-250V) for 5 min, split into 10 min subruns, with CDMS and NaI detectors running and DCRC2 as HV controller. Using sequence HVscan-240×1-4_5PreBias-DCRC2_250–30Flash-30wait-2hrData-10minSubRun.msl
CDMS detector: Driver Gains = 2x, QET biases = (280/260/305)/(140/280/295) uA, Front-End Gains = (10/10/10)/(10/15/10)
NaI detector: 1.1kV → NaI B/C → Ortec 452(gain=5, shaping = 6 us, output=10V, Neg) / Ortec 575A(gain=10, shaping = 3us, Neg) → x10/x10 attenuator → DCRC4PB/PA, Driver Gains = 1/1, PhononWaveFormLength = 1024 (512 samples), PhononPrepulseSamples = 64 (64 samples)
1000 BOR randoms, trigger on DCRC3pB/C/D threshold = 7/10/9
1348 Return 22Na source to safe.
1350 A quick analysis seems to show the noise resolution is a little worse at this bias than at -80V. It could be that what leakage is present has pushed the TESs away from the optimal bias point. Let's play with QET biases a little at -240V. Chose the following by hand, going a little bit above the SC region. QET biases = (270/258/285)/(135/278/292)
1400 Still biased at -240V, let's take some data like this.
1407 Start 1 hr, -240 V bkg dataset, split into 10 min subruns, with CDMS and NaI detectors running and DCRC2 as HV controller. Using sequence timed_subrun.msl
CDMS detector: Driver Gains = 2x, QET biases = (270/258/285)/(135/278/292) uA, Front-End Gains = (10/10/10)/(10/15/10)
NaI detector: 1.1kV → NaI B/C → Ortec 452(gain=5, shaping = 6 us, output=10V, Neg) / Ortec 575A(gain=10, shaping = 3us, Neg) → x10/x10 attenuator → DCRC4PB/PA, Driver Gains = 1/1, PhononWaveFormLength = 1024 (512 samples), PhononPrepulseSamples = 64 (64 samples)
1000 BOR randoms, trigger on DCRC3pB/D threshold = 8/10
Using a similar method to this, it seems like the noise is worse, σ = 30.4 eVee, in this configuration.
1421 DCRC3pC is railed, recover it.
1513 Turn down HV using change_HV_240_to_0_DCRC2_250V.msl
1530 Bring PuBe source into lab and place at south wall of lab.
1534 Flash detector.
1535 Start 1hr NaI calibration dataset with NaI detector: 1.1kV → NaI B/C → → Ortec 452(gain=5, shaping = 6 us, output=10V, Neg) / Ortec 575A(gain=10, shaping = 3us, Neg) → x10/x10 attenuator → DCRC4PB/PA, Driver Gains = 1/1, PhononWaveFormLength = 1024 (512 samples), PhononPrepulseSamples = 64 (64 samples)
1000 BOR randoms, trigger on DCRC4pA/B threshold = 5/5
This dataset still didn't show the 4.4MeV gamma line as expected. Not sure what's going on here…
1705 Move PuBe source to standard position behind lead heap on west side of fridge.
1707 Fill LN2 cold trap full.
1721 Restore standard QET biases = QET biases = (280/260/305)/(140/280/295) uA
Note: It was later discovered that they were actually set to : (280/280/305)/(140/280/295) uA
1735 Doesn't look like the NaI signal will be much different and the -240V data has a little worse noise that -80V. So we don't have a clear way to improve on what's been done already. Maybe there is an optimal bias between -80V and -240V? Let's do a bias scan overnight to check it out. If there's a clear improvement, then we can use it for PuBe search data over the weekend.
0938 Start PuBe bias scan sequence of 1 hr datasets at HV = 0,-50,-75,-100,-125,-150,-175,-200,-225 V with 10% prebias for 5 min, split into 10 min subruns, with CDMS and NaI detectors running and DCRC2 as HV controller. Using sequence HVscan-0_50_75_100_125_150_175_200_225-10_5PreBias-DCRC2_250V-30Flash-30wait-1hrData-10minSubRun.msl
CDMS detector: Driver Gains = 2x, QET biases = (280/260/305)/(140/280/295) uA, Front-End Gains = (10/10/10)/(10/15/10)
NaI detector: 1.1kV → NaI B/C → Ortec 452(gain=5, shaping = 6 us, output=10V, Neg) / Ortec 575A(gain=10, shaping = 3us, Neg) → x10/x10 attenuator → DCRC4PB/PA, Driver Gains = 1/1, PhononWaveFormLength = 1024 (512 samples), PhononPrepulseSamples = 64 (64 samples)
1000 BOR randoms, trigger on DCRC3pB/C/D threshold = 7/10/9