| Table 2: Log of Plastic Scintillator Samples (fabricated by David-Michael) |
| Date Fabricated | Sample Label | Mass % Loaded Compound | Loaded Compound Used | Length (+/- 0.002 cm), Diameter (+/- 0.002cm) | Notes on Fabrication Process | Notes on Fabricated PS | Image of PS |
| | DMR-17D | 0% wt. Gd | NONE | | Polymerized in water bath | | |
| | DMR-17C | 0% wt. Gd | NONE | | Polymerized in Test Equity oven | | |
| | DMR-17B | 0% wt. Gd | NONE | N/A | Polymerized in Test Equity oven | Fiber as well as glue holding fiber mounts melted during polymerization. Sample failed. | |
| | DMR-17A | 0% wt. Gd | NONE | N/A | Polymerized in water bath | Sample was still not polymerized after 10 days. Sample became cloudy. Sample failed. | |
| | | | | | | | |
| 2017/07/08 | DMR-16G | 0% wt. Gd | NONE | | | | |
| 2017/07/08 | DMR-16F | 0.5% wt. Gd | Gd(TMHD)3 | | | | |
| 2017/07/08 | DMR-16E | 0% wt. Gd | NONE | | | | |
| 2017/07/08 | DMR-16D | 0% wt. Gd | NONE | | | | |
| 2017/07/08 | DMR-16C | 0% wt. Gd | NONE | | | | |
| 2017/07/08 | DMR-16B | 0% wt. Gd | NONE | | | | |
| 2017/07/08 | DMR-16A | 0% wt. Gd | NONE | | | | |
| | | | | | | | |
| 2017/06/12 | DMR-15A | 0% wt. Gd | NONE | | | | |
| 2017/06/12 | DMR-15C | 0.055% wt. Gd | Gd(i-Pr)3 | | | | |
| 2017/06/12 | DMR-15D | 0.055% wt. Gd | Gd(TMHD)3 | | | | |
| 2017/06/12 | DMR-15E | 0.1% wt. Gd | Gd(i-Pr)3 | | | | |
| 2017/06/12 | DMR-15F | 0.1% wt. Gd | Gd(TMHD)3 | | | | |
| 2017/06/12 | DMR-15G | 0.5% wt. Gd | Gd(i-Pr)3 | | | | |
| 2017/06/12 | DMR-15H | 0.5% wt. Gd | Gd(TMHD)3 | | | | |
| | | | | | | | |
| 2016/01/27 | DMR-01 | NONE | NONE | 3.192, 2.489 | Fluors added, no Gd, vial did not crack but samples were placed in reservoir for duration of polymerization | | |
| 2016/02/03 | DMR-02 | 0.1% | GdTIP-01 | | | | |
| 2016/02/10 | DMR-03 | 0.1% | GdTIP-02 | | | | |
| 2016/02/17 | DMR-04 | 0.05% | GdTIP-02 | | | Deformity at top | |
| 2016/02/17 | DMR-05 | 0.1% | GdTIP-02 | | | | |
| 2016/05/04 | DMR-06 | 0.1% | GdTIP-04 | 2.772, 2.492 | Filtered | | |
| 2016/05/25 | DMR-07 | 0.05% | GdTIP-04 | 3.756, 2.498 | Filtered | | |
| 2016/06/03 | DMR-08 | 0.2% | GdTIP-04 | | Filtered, bath ran out of water part way through polymerization | | |
| 2016/06/16 | DMR-09 | 0.15% | GdTIP-04 | 3.781, 2.489 | Filtered | | |
| 2016/08/17 | DMR-10A | NONE | NONE | 5.900, 2.490 | | | |
| 2016/08/17 | DMR-10B | NONE | NONE | 6.124, 2.492 | | | |
| 2016/08/17 | DMR-10C | NONE | NONE | 6.040, 2.497 | | | |
| 2016/08/17 | DMR-10D | NONE | NONE | 6.252, 2.498 | | | |
| 2016/08/17 | DMR-10 (A,B,C,D cemented together) | NONE | NONE | 24.32 | | | |
| 2016/12/04 | DMR-12A | NONE | NONE | | | | |
| 2016/12/04 | DMR-12B | NONE | NONE | 5.768, 2.495 | | | |
| 2016/12/04 | DMR-12C | NONE | NONE | 6.193, 2.498 | | | |
| 2016/12/04 | DMR-12D | NONE | NONE | 6.088, 2.500 | | | |
| 1017/01/03 | DMR-12 (A,B,C,D cemented together) | NONE | NONE | | | | |
| | | | | | | | |