| 1100 | Fill LN2 cold trap full. |
| 1110 | Adjust 1K pot needle valve. |
| 2210 | Mixing chamber temperature has increased from 1.65 K to 1.68 K over the course of the day. Temperature of 1 K pot is still unstable, varying from 1.6 K to 1.65 K. Leave 1 K pot as it is for now. |
| | Plugged DCRC31 into DIB 1, DCRC33 into DIB 2. Left connected and monitored for a few hours: everything looks stable. It appears as though problem with DCRC33 hasn't reoccurred. |
| | Commence data acquisition, starting with 8-hour flash followed by 2-hour cooldown. OR trigger on charge channels only: Qi DIB 1 = 32 ADC bins; Qo DIB 1 = 19 ADC bins; Qi DIB 2 ADC bins = 32 ADC bins; & Qo DIB 2 = 21 ADC bins. One half-hour data series for biases in following order: -/+4 V; & +/-4 V. Data series separated by 10 minute flash follwoed by 60 minute cooldown. |
| 2220 | Unsure if LEDs are working as unable to see a change in temperature. It's probably fine as mixing chamber temperature of 1.68 K may be too high to see any difference. |
| 2255 | Fill N2 cold trap full. |