| Table 1: UMN Made Stripline Pinouts by Wire Bundle |
| Bundle | Stripline D Socket | Breakout Box | Material |
| 1 | 50 and 32 | Squid bias B (34) and Squid ret B (19) | CuBe |
| 1 | 33 and 16 | feedback ret B (18) and feedback coil B (2) | manganin |
| 1 | 11 and 9 | QET C (7) and QET ret C 2 (9) | manganin |
| 1 | 31 and 14 | Squid ret A (20) and Squid bias A (4) | CuBe |
| 1 | 47 and 30 | feedback coil A (37) and feedback ret A (21) | manganin |
| 2 | 46 and 48 | QET D (38) and QET ret D 1 (36) | manganin |
| 2 | 45 and 28 | Squid ret D (39) and Squid bias D (23) | CuBe |
| 2 | 5 and 4 | QET ret A 2 (14) and QET ret A 3 (13) | manganin |
| 2 | 12 and 29 | feedback ret D (6) and feedback coil D (22) | manganin |
| 2 | 15 and 17 | QET A (3) and QET ret A 1 (1) | manganin |
| 3 | 1 and 18 | QET ret A 5 (17) and QET ret B 4 (33) | manganin |
| 3 | 2 and 20 | Qi drain (16) and Qi source (31) | CuBe |
| 3 | 39 and 38 | FET heater + (45) and FET heater - (46) | manganin |
| 3 | 43 and 26 | feedback coil C (41) and feedback ret C (25) | manganin |
| 3 | 25 and 42 | LED 2 (26) and LED 1 (42) | manganin |
| 4 | 36 and 37 | QET ret B 3 (48) and QET ret B 2 (47) | manganin |
| 4 | 41 and 40 | QET ret D 3 (43) and QET Ret D 4 (44) | manganin |
| 4 | 10 and 27 | Squid bias C (8) and Squid ret C (24) | CuBe |
| 4 | 44 and 22 | QET ret D 2 (40) and QET ret B 1 (29) | manganin |
| 4 | 8 and 23 | QET ret C 3 (10) and QET ret C 4 (28) | manganin |
| 5 | 49 and 13 | QET B (39) and QET ret C 1 (13) | manganin |
| 5 | 19 and 35 | QET ret A 4 (32) and FET tsense + (49) | manganin |
| 5 | 3 and 34 | Qi bias (15) and Qi feedback (50) | manganin |
| 5 | 7 and 21 | Qo bias (11) and Qo feedback (30) | manganin |
| 5 | 6 and 24 | Qo drain (12) and Qo source (27) | CuBe |