UMN CDMS Wiki archive
start › cdms › k100 › run_diary › 20110406

2011/4/6

0659 Stop the run at 07110406_0553. Temperature was not stable during midnight. This must due to ventilation system stop. The was also observed the day before.
Temperature fluctuation during midnight
0708 Start to take data 07110406_0708_F0001. Calibrated -8V on Q1-4
0925 Filled N2 cold trap.
1107 Matt took LS370
1527 Stop the run at 07110406_1442_F0004. Matt returned the LS370.
1558 Start taking data 07110406_1558_F0001. Calibrated -2V on Q1-4. Trigger: Q1(30ADC) OR Q2(30ADC) OR Q3(30ADC) OR Q4(30ADC); coincidence time 50us. Trace length 1024, lookback time 100us. DCRC30 on DIB1, ZIP2, master; DCRC33 on DIB2, ZIP1, slave. Auto run enabled, take data 15min, flash 20min, cooldown 40min. Flash settings: DIB2, LED 1&2; DIB1, LED1; LED current 0.6mA, 100us ON, 2500us OFF. Tower T 63.5mK.
1918 Noticed some files are smaller than others when copying data. Don't what happened.
$ scp -r  07110406_0[7-9]*  07110406_1* zhang@masherbrum.spa.umn.edu:/data/snowdon/k100/raw/byseries
07110406_0708_F0001                                                                       100%  163MB  27.2MB/s   00:06
07110406_0708_F0002                                                                       100%  163MB  40.8MB/s   00:04
07110406_0708_F0003                                                                       100%  163MB  27.2MB/s   00:06
07110406_0708_F0004                                                                       100%   99MB  49.3MB/s   00:02
07110406_0823_F0001                                                                       100%  163MB  32.6MB/s   00:05
07110406_0823_F0002                                                                       100%  163MB  32.6MB/s   00:05
07110406_0823_F0003                                                                       100%  163MB  32.6MB/s   00:05
07110406_0823_F0004                                                                       100%  163MB  40.8MB/s   00:04
07110406_0823_F0005                                                                       100%    8     0.0KB/s   00:00
07110406_0940_F0001                                                                       100%  163MB  40.8MB/s   00:04
07110406_0940_F0002                                                                       100%  163MB  40.8MB/s   00:04
07110406_0940_F0003                                                                       100%  161MB  40.2MB/s   00:04
07110406_1056_F0001                                                                       100%  163MB  40.8MB/s   00:04
07110406_1056_F0002                                                                       100%  163MB  32.6MB/s   00:05
07110406_1056_F0003                                                                       100%  109MB  36.3MB/s   00:03
07110406_1212_F0001                                                                       100%  163MB  32.6MB/s   00:05
07110406_1212_F0002                                                                       100%  163MB  32.6MB/s   00:05
07110406_1212_F0003                                                                       100%  163MB  32.6MB/s   00:05
07110406_1212_F0004                                                                       100%    8     0.0KB/s   00:00
07110406_1327_F0001                                                                       100%  163MB  32.6MB/s   00:05
07110406_1327_F0002                                                                       100%  163MB  32.6MB/s   00:05
07110406_1327_F0003                                                                       100%  147MB  24.5MB/s   00:06
07110406_1442_F0001                                                                       100%  163MB  40.8MB/s   00:04
07110406_1442_F0002                                                                       100%  163MB  40.8MB/s   00:04
07110406_1442_F0003                                                                       100%  163MB  32.6MB/s   00:05
07110406_1442_F0004                                                                       100%    8     0.0KB/s   00:00
07110406_1558_F0001                                                                       100%  163MB  32.6MB/s   00:05
07110406_1558_F0002                                                                       100%  163MB  40.8MB/s   00:04
07110406_1558_F0003                                                                       100%  134MB  44.5MB/s   00:03
07110406_1716_F0001                                                                       100%  163MB  40.8MB/s   00:04
07110406_1716_F0002                                                                       100%  163MB  54.4MB/s   00:03
07110406_1716_F0003                                                                       100%  163MB  40.8MB/s   00:04
07110406_1716_F0004                                                                       100%    8     0.0KB/s   00:00
07110406_1836_F0001                                                                       100%  163MB  32.6MB/s   00:05
07110406_1836_F0002                                                                       100%  163MB  32.6MB/s   00:05
07110406_1836_F0003                                                                       100%   57MB  57.2MB/s   00:01
2000 Filled N2 cold trap.
2309 Stop DAQ after 20min flashing. 6 data sets were taken for -2V bias. Stopped at 07110406_2229_F0003.
2326 Copied rq to nero upto 07110406_2229
2345 Start to take data 07110406_2345_F001. Calibrated -1V on Q1-4. Trigger: Q1(30ADC) OR Q2(30ADC) OR Q3(30ADC) OR Q4(30ADC); coincidence time 50us. Trace length 1024, lookback time 100us. DCRC30 on DIB1, ZIP2, master; DCRC33 on DIB2, ZIP1, slave. Auto run enabled, take data 60min, flash 20min, cooldown 40min. Flash settings: DIB2, LED 1&2; DIB1, LED1; LED current 0.6mA, 100us ON, 2500us OFF. Tower T 61.2mK.

Calibrated -8V bias

Data:

07110406_0708
07110406_0823
07110406_0940
07110406_1056
07110406_1212
07110406_1327
07110406_1442

Scipt

The cuts are defined as

  • cQ# = max([Q1, Q2, Q3, Q4], [], 2)==#
  • cQCchisq = cQ1chisq & cQ2chisq & cQ3chisq & cQ4chisq
  • cE1 = 15 < Q1;
  • cE2 = 15 < Q2;
  • cE3 = 10 < Q3;
  • cE4 = 20 < Q4;
  • cE = 50 < Qsum.

Comments:

Script

Plots

Calibrated -2V bias

Data:

07110406_1558
07110406_1716
07110406_1836
07110406_1951
07110406_2109
07110406_2229

Scipt

The cuts are defined as

  • cQ# = max([Q1, Q2, Q3, Q4], [], 2)==#
  • cQCchisq = cQ1chisq & cQ2chisq & cQ3chisq & cQ4chisq
  • cE1 = 15 < Q1;
  • cE2 = 15 < Q2;
  • cE3 = 10 < Q3;
  • cE4 = 20 < Q4;
  • cE = 50 < Qsum.

Plots

Calibrated -1V bias

Data:

07110406_2345
07110407_0103
07110407_0219
07110407_0335
07110407_0451
07110407_0606
07110407_0722
07110407_0838

Scipt

Q#f = Q#/Qsum

The cuts are defined as

  • cQ# = max([Q1, Q2, Q3, Q4], [], 2)==#
  • cQCchisq = cQ1chisq & cQ2chisq & cQ3chisq & cQ4chisq
  • cE1 = 15 < Q1;
  • cE2 = 15 < Q2;
  • cE3 = 10 < Q3;
  • cE4 = 20 < Q4;
  • cE = 50 < Qsum.

Plots