 Temp.     Resistance      Sensitivity     Dimensionless
 (Kelvin)  (Ohms)          (Ohms/Kelvin)   Sensitivity
 
    0.020   7.189756E+03   -1.803031E+05   -5.0156E-01
    0.022   6.855260E+03   -1.544103E+05   -4.9554E-01
    0.024   6.569815E+03   -1.319317E+05   -4.8196E-01
    0.026   6.324046E+03   -1.145815E+05   -4.7108E-01
    0.028   6.108805E+03   -1.011956E+05   -4.6383E-01
    0.030   5.917485E+03   -9.051999E+04   -4.5891E-01
    0.032   5.745518E+03   -8.170637E+04   -4.5507E-01
    0.034   5.589712E+03   -7.429080E+04   -4.5188E-01
    0.036   5.447685E+03   -6.788636E+04   -4.4861E-01
    0.038   5.317628E+03   -6.229190E+04   -4.4514E-01
    0.040   5.198083E+03   -5.735498E+04   -4.4135E-01
    0.042   5.087836E+03   -5.297494E+04   -4.3731E-01
    0.044   4.985866E+03   -4.907149E+04   -4.3305E-01
    0.046   4.891275E+03   -4.558273E+04   -4.2868E-01
    0.048   4.803293E+03   -4.245744E+04   -4.2428E-01
    0.050   4.721235E+03   -3.964899E+04   -4.1990E-01
    0.055   4.538267E+03   -3.378593E+04   -4.0946E-01
    0.060   4.381206E+03   -2.921711E+04   -4.0012E-01
    0.065   4.244517E+03   -2.560203E+04   -3.9207E-01
    0.070   4.124057E+03   -2.267867E+04   -3.8494E-01
    0.075   4.016820E+03   -2.029934E+04   -3.7902E-01
    0.080   3.920413E+03   -1.832018E+04   -3.7384E-01
    0.085   3.833080E+03   -1.666179E+04   -3.6948E-01
    0.090   3.753407E+03   -1.524201E+04   -3.6548E-01
    0.095   3.680328E+03   -1.402166E+04   -3.6194E-01
    0.100   3.612906E+03   -1.296855E+04   -3.5895E-01
    0.110   3.492362E+03   -1.121421E+04   -3.5322E-01
    0.120   3.387359E+03   -9.833655E+03   -3.4837E-01
    0.130   3.294821E+03   -8.713858E+03   -3.4381E-01
    0.140   3.212453E+03   -7.786994E+03   -3.3936E-01
    0.150   3.138568E+03   -7.012595E+03   -3.3515E-01
    0.160   3.071826E+03   -6.352938E+03   -3.3090E-01
    0.170   3.011187E+03   -5.788713E+03   -3.2681E-01
    0.180   2.955807E+03   -5.298756E+03   -3.2268E-01
    0.190   2.904994E+03   -4.873009E+03   -3.1872E-01
    0.200   2.858180E+03   -4.497915E+03   -3.1474E-01
    0.210   2.814883E+03   -4.168135E+03   -3.1096E-01
    0.220   2.774699E+03   -3.874257E+03   -3.0718E-01
    0.230   2.737289E+03   -3.613032E+03   -3.0358E-01
    0.240   2.702347E+03   -3.379319E+03   -3.0012E-01
    0.250   2.669628E+03   -3.168028E+03   -2.9667E-01
    0.260   2.638916E+03   -2.977932E+03   -2.9340E-01
    0.270   2.610009E+03   -2.806199E+03   -2.9030E-01
    0.280   2.582738E+03   -2.650438E+03   -2.8734E-01
    0.290   2.556949E+03   -2.509899E+03   -2.8466E-01
    0.300   2.532508E+03   -2.379167E+03   -2.8184E-01
    0.320   2.487378E+03   -2.146178E+03   -2.7610E-01
    0.340   2.445948E+03   -2.002049E+03   -2.7830E-01
    0.360   2.407549E+03   -1.830176E+03   -2.7367E-01
    0.380   2.372957E+03   -1.632615E+03   -2.6144E-01
    0.400   2.341948E+03   -1.475759E+03   -2.5206E-01
    0.420   2.313634E+03   -1.362634E+03   -2.4736E-01
    0.440   2.287299E+03   -1.272412E+03   -2.4477E-01
    0.460   2.262679E+03   -1.190955E+03   -2.4212E-01
    0.480   2.239605E+03   -1.117810E+03   -2.3957E-01
    0.500   2.217920E+03   -1.051732E+03   -2.3710E-01
    0.550   2.168953E+03   -9.126289E+02   -2.3142E-01
    0.600   2.126255E+03   -7.987635E+02   -2.2540E-01
    0.650   2.088755E+03   -7.040437E+02   -2.1909E-01
    0.700   2.055582E+03   -6.253668E+02   -2.1296E-01
    0.750   2.026007E+03   -5.595879E+02   -2.0715E-01
    0.800   1.999440E+03   -5.045990E+02   -2.0190E-01
    0.850   1.975408E+03   -4.580538E+02   -1.9710E-01
    0.900   1.953516E+03   -4.185414E+02   -1.9283E-01
    0.950   1.933464E+03   -3.844037E+02   -1.8888E-01
    1.000   1.914995E+03   -3.550291E+02   -1.8539E-01
    1.050   1.897902E+03   -3.292657E+02   -1.8216E-01
    1.100   1.882017E+03   -3.065683E+02   -1.7918E-01
    1.150   1.867203E+03   -2.864280E+02   -1.7641E-01
    1.200   1.853338E+03   -2.684949E+02   -1.7385E-01
    1.300   1.828077E+03   -2.377666E+02   -1.6908E-01
    1.400   1.805600E+03   -2.125942E+02   -1.6484E-01
    1.500   1.785423E+03   -1.915057E+02   -1.6089E-01
    1.600   1.767189E+03   -1.736968E+02   -1.5726E-01
    1.700   1.750596E+03   -1.585160E+02   -1.5393E-01
    1.800   1.735417E+03   -1.454023E+02   -1.5081E-01
    1.900   1.721458E+03   -1.340201E+02   -1.4792E-01
    2.000   1.708566E+03   -1.240578E+02   -1.4522E-01
    2.100   1.696606E+03   -1.152993E+02   -1.4271E-01
    2.200   1.685473E+03   -1.075420E+02   -1.4037E-01
    2.300   1.675069E+03   -1.006486E+02   -1.3820E-01
    2.400   1.665319E+03   -9.448415E+01   -1.3617E-01
    2.500   1.656151E+03   -8.895504E+01   -1.3428E-01
    2.600   1.647509E+03   -8.396959E+01   -1.3252E-01
    2.700   1.639341E+03   -7.946143E+01   -1.3087E-01
    2.800   1.631603E+03   -7.536641E+01   -1.2934E-01
    2.900   1.624256E+03   -7.163752E+01   -1.2790E-01
    3.000   1.617265E+03   -6.822838E+01   -1.2656E-01
    3.100   1.610601E+03   -6.510374E+01   -1.2531E-01
    3.200   1.604236E+03   -6.223006E+01   -1.2413E-01
    3.300   1.598147E+03   -5.958250E+01   -1.2303E-01
    3.400   1.592313E+03   -5.713422E+01   -1.2200E-01
    3.500   1.586714E+03   -5.486690E+01   -1.2103E-01
    3.600   1.581334E+03   -5.276202E+01   -1.2012E-01
    3.700   1.576157E+03   -5.080255E+01   -1.1926E-01
    3.800   1.571169E+03   -4.897029E+01   -1.1844E-01
    3.900   1.566359E+03   -4.726374E+01   -1.1768E-01
    4.000   1.561713E+03   -4.568157E+01   -1.1700E-01
    4.200   1.552876E+03   -4.269816E+01   -1.1548E-01
    4.400   1.544613E+03   -4.001428E+01   -1.1399E-01
    4.600   1.536837E+03   -3.783496E+01   -1.1325E-01
    4.800   1.529459E+03   -3.596179E+01   -1.1286E-01
    5.000   1.522445E+03   -3.420034E+01   -1.1232E-01
    5.200   1.515771E+03   -3.256471E+01   -1.1172E-01
    5.400   1.509409E+03   -3.106979E+01   -1.1115E-01
    5.600   1.503334E+03   -2.970869E+01   -1.1067E-01
    5.800   1.497519E+03   -2.845551E+01   -1.1021E-01
    6.000   1.491945E+03   -2.730433E+01   -1.0981E-01
    6.500   1.478932E+03   -2.483369E+01   -1.0915E-01
    7.000   1.467035E+03   -2.282761E+01   -1.0892E-01
    7.500   1.456044E+03   -2.118048E+01   -1.0910E-01
    8.000   1.445809E+03   -1.980339E+01   -1.0958E-01
    8.500   1.436205E+03   -1.863803E+01   -1.1031E-01
    9.000   1.427145E+03   -1.762786E+01   -1.1117E-01
    9.500   1.418557E+03   -1.674297E+01   -1.1213E-01
   10.000   1.410386E+03   -1.595349E+01   -1.1311E-01
   10.500   1.402590E+03   -1.524240E+01   -1.1411E-01
   11.000   1.395134E+03   -1.459315E+01   -1.1506E-01
   11.500   1.387988E+03   -1.399602E+01   -1.1596E-01
   12.000   1.381131E+03   -1.344196E+01   -1.1679E-01
   12.500   1.374540E+03   -1.292556E+01   -1.1754E-01
   13.000   1.368200E+03   -1.244148E+01   -1.1821E-01
   13.500   1.362094E+03   -1.198650E+01   -1.1880E-01
   14.000   1.356209E+03   -1.155758E+01   -1.1931E-01
   14.500   1.350532E+03   -1.115262E+01   -1.1974E-01
   15.000   1.345052E+03   -1.076967E+01   -1.2010E-01
   15.500   1.339759E+03   -1.040725E+01   -1.2040E-01
   16.000   1.334642E+03   -1.006397E+01   -1.2065E-01
   16.500   1.329692E+03   -9.738655E+00   -1.2085E-01
   17.000   1.324901E+03   -9.430203E+00   -1.2100E-01
   17.500   1.320259E+03   -9.137612E+00   -1.2112E-01
   18.000   1.315760E+03   -8.859939E+00   -1.2121E-01
   18.500   1.311397E+03   -8.596280E+00   -1.2127E-01
   19.000   1.307162E+03   -8.345825E+00   -1.2131E-01
   19.500   1.303049E+03   -8.107742E+00   -1.2133E-01
   20.000   1.299052E+03   -7.881216E+00   -1.2134E-01
   21.000   1.291385E+03   -7.460398E+00   -1.2132E-01
   22.000   1.284119E+03   -7.077884E+00   -1.2126E-01
   23.000   1.277218E+03   -6.729256E+00   -1.2118E-01
   24.000   1.270651E+03   -6.409948E+00   -1.2107E-01
   25.000   1.264389E+03   -6.116950E+00   -1.2095E-01
   26.000   1.258409E+03   -5.846716E+00   -1.2080E-01
   27.000   1.252689E+03   -5.596641E+00   -1.2063E-01
   28.000   1.247210E+03   -5.364590E+00   -1.2044E-01
   29.000   1.241955E+03   -5.148308E+00   -1.2021E-01
   30.000   1.236908E+03   -4.946256E+00   -1.1997E-01
   31.000   1.232058E+03   -4.756918E+00   -1.1969E-01
   32.000   1.227391E+03   -4.578993E+00   -1.1938E-01
   33.000   1.222896E+03   -4.411549E+00   -1.1905E-01
   34.000   1.218564E+03   -4.253520E+00   -1.1868E-01
   35.000   1.214387E+03   -4.103849E+00   -1.1828E-01
   36.000   1.210354E+03   -3.962388E+00   -1.1785E-01
   37.000   1.206459E+03   -3.828341E+00   -1.1741E-01
   38.000   1.202695E+03   -3.700925E+00   -1.1693E-01
   39.000   1.199055E+03   -3.580031E+00   -1.1644E-01
   40.000   1.195533E+03   -3.465025E+00   -1.1593E-01