Temperature Resistance (Kelvin) (Ohms) 1.67022156472510E-02 7.82670100000000E+03 1.84750153181460E-02 7.44960100000000E+03 2.03155903500950E-02 7.13090100000000E+03 2.24958810032280E-02 6.77860100000000E+03 2.43366641775580E-02 6.54200100000000E+03 2.69678965802370E-02 6.23030100000000E+03 2.95985476114930E-02 5.96050100000000E+03 3.25493081380000E-02 5.69220400000000E+03 3.47708691960000E-02 5.52080400000000E+03 3.69820840636140E-02 5.37820100000000E+03 3.99483405960000E-02 5.19490400000000E+03 4.38794177940000E-02 4.99103400000000E+03 4.75981142530450E-02 4.82062100000000E+03 5.16145438650000E-02 4.66546400000000E+03 5.69922422430000E-02 4.48358400000000E+03 6.40852951574550E-02 4.26860100000000E+03 7.37523855847180E-02 4.04028100000000E+03 8.34531317807390E-02 3.85720100000000E+03 9.58426778255020E-02 3.66549100000000E+03 1.11402023663000E-01 3.47596400000000E+03 1.28105222751403E-01 3.31219100000000E+03 1.46091165392000E-01 3.16766400000000E+03 1.63780188579000E-01 3.04858400000000E+03 1.83352766274000E-01 2.93935400000000E+03 2.04944582141000E-01 2.83687400000000E+03 2.30062416525153E-01 2.73623200000000E+03 2.59262446414000E-01 2.64000400000000E+03 2.89711388923000E-01 2.55734400000000E+03 3.10008767963789E-01 2.50934100000000E+03 3.29979373733656E-01 2.46732200000000E+03 3.68018310751944E-01 2.39480200000000E+03 4.18070341087993E-01 2.31610200000000E+03 4.75986303751527E-01 2.24267200000000E+03 5.34947151533877E-01 2.18331300000000E+03 6.10165675318847E-01 2.11871300000000E+03 6.84913764530805E-01 2.06559300000000E+03 7.64697918956733E-01 2.01804300000000E+03 8.55069973642000E-01 1.97262400000000E+03 9.63560478845000E-01 1.92782400000000E+03 1.05201618800000E+00 1.89725400000000E+03 1.14642911883084E+00 1.86851699416007E+03 1.19711333018350E+00 1.85433134593461E+03 1.29837878365563E+00 1.82848270130289E+03 1.39959148843003E+00 1.80577016320761E+03 1.59654167369308E+00 1.76759201182740E+03 1.79917110427464E+00 1.73544225482742E+03 2.00053946781735E+00 1.70859110657643E+03 2.20065064614719E+00 1.68536474369178E+03 2.40120238564745E+00 1.66524789675485E+03 2.60112689280060E+00 1.64749114903615E+03 2.79999812707006E+00 1.63154970361300E+03 2.99982886176998E+00 1.61730018787722E+03 3.20185505097695E+00 1.60402778223739E+03 3.40240528132931E+00 1.59224239453202E+03 3.60249473369434E+00 1.58118927657256E+03 3.80244735575910E+00 1.57111731099977E+03 4.00238080081564E+00 1.56148880010061E+03 4.20212793698209E+00 1.55278397255581E+03 4.60111625947044E+00 1.53681906253439E+03 5.00152745158370E+00 1.52235051664714E+03 5.49894740730708E+00 1.50635210107976E+03 6.19936936689657E+00 1.48660249637780E+03 7.00430324730765E+00 1.46700483407138E+03 8.00088691009040E+00 1.44576071538735E+03 9.00437023717542E+00 1.42704130193908E+03 1.00017304460897E+01 1.41036393512045E+03 1.09997072148208E+01 1.39521318171516E+03 1.19976105337658E+01 1.38108155238301E+03 1.29974150516983E+01 1.36822720533854E+03 1.39987416381444E+01 1.35624223452361E+03 1.49974117967448E+01 1.34505710782991E+03 1.59970313437374E+01 1.33465410451924E+03 1.69983266893284E+01 1.32494379357986E+03 1.79960637494282E+01 1.31588968610245E+03 1.89979051985370E+01 1.30716230600579E+03 2.00864343335156E+01 1.29834324998490E+03 2.11526456684418E+01 1.29022522038880E+03 2.27203385217115E+01 1.27909452007319E+03 2.43245822378735E+01 1.26859480364074E+03 2.59089925284041E+01 1.25888190768394E+03 2.74982780272860E+01 1.24994554723010E+03 2.90955198959882E+01 1.24155108649590E+03 3.09037917703841E+01 1.23253985438961E+03 3.29932685630422E+01 1.22287164949835E+03 3.59946230948415E+01 1.21034254789998E+03 3.89957250679082E+01 1.19909728976599E+03 4.19924442361965E+01 1.18885082244478E+03 4.49849135540091E+01 1.17954394212059E+03
start › cdms › coldhardware › thermometer › u09212_dat