Sensor Model: RX-102B-RS-0.02B Serial Number: U09212 Data Format: 7 (Ohms/Kelvin) Setpoint Limit: 40 Measurement (ohms) Temp (K) Curvature 1.17954E+03 4.49866E+01 3.33158E-03 1.18885E+03 4.19908E+01 2.96504E-03 1.19910E+03 3.89883E+01 2.56149E-03 1.21034E+03 3.60029E+01 2.20832E-03 1.22287E+03 3.30056E+01 1.89016E-03 1.23254E+03 3.08989E+01 1.69286E-03 1.24155E+03 2.90785E+01 1.53544E-03 1.24995E+03 2.74954E+01 1.40952E-03 1.25888E+03 2.59193E+01 1.29227E-03 1.26859E+03 2.43232E+01 1.18091E-03 1.27909E+03 2.27230E+01 1.07472E-03 1.29023E+03 2.11561E+01 9.74591E-04 1.29834E+03 2.00902E+01 9.07767E-04 1.30716E+03 1.90000E+01 8.39605E-04 1.31589E+03 1.79854E+01 7.76684E-04 1.32494E+03 1.69954E+01 7.15650E-04 1.33465E+03 1.59988E+01 6.55023E-04 1.34506E+03 1.49996E+01 5.95748E-04 1.35624E+03 1.39971E+01 5.38870E-04 1.36823E+03 1.29978E+01 4.86168E-04 1.38108E+03 1.20036E+01 4.39246E-04 1.39521E+03 1.09946E+01 3.98873E-04 1.41036E+03 1.00014E+01 3.67303E-04 1.42704E+03 9.00590E+00 3.43469E-04 1.44576E+03 8.00245E+00 3.24926E-04 1.46700E+03 7.00131E+00 3.04860E-04 1.48660E+03 6.19954E+00 2.79663E-04 1.50635E+03 5.49952E+00 2.43860E-04 1.52235E+03 5.00275E+00 2.12873E-04 1.53682E+03 4.60047E+00 1.80287E-04 1.55278E+03 4.20215E+00 1.92347E-04 1.56149E+03 4.00490E+00 1.58198E-04 1.57112E+03 3.80106E+00 1.51469E-04 1.58119E+03 3.60275E+00 1.38005E-04 1.59224E+03 3.40124E+00 1.26297E-04 1.60403E+03 3.20335E+00 1.14450E-04 1.61730E+03 2.99949E+00 1.02541E-04 1.63155E+03 2.80071E+00 9.11149E-05 1.64749E+03 2.60022E+00 7.98668E-05 1.66525E+03 2.40075E+00 6.90232E-05 1.68536E+03 2.20100E+00 5.85981E-05 1.70859E+03 1.99980E+00 4.86535E-05 1.73544E+03 1.79983E+00 3.94577E-05 1.76759E+03 1.59768E+00 3.09788E-05 1.80577E+03 1.39920E+00 2.37294E-05 1.82848E+03 1.29830E+00 2.05106E-05 1.85433E+03 1.19631E+00 1.74225E-05 1.86852E+03 1.14542E+00 1.60001E-05 1.89725E+03 1.05197E+00 1.35283E-05 1.92782E+03 9.64851E-01 1.14085E-05 1.97262E+03 8.56112E-01 8.98366E-06 2.01804E+03 7.64452E-01 7.10285E-06 2.06559E+03 6.84280E-01 5.54312E-06 2.11871E+03 6.09559E-01 4.18971E-06 2.18331E+03 5.34594E-01 3.04112E-06 2.24267E+03 4.77268E-01 2.41706E-06 2.31610E+03 4.18195E-01 1.97733E-06 2.39480E+03 3.67103E-01 1.93921E-06 2.46732E+03 3.29514E-01 5.95198E-07 2.50934E+03 3.10004E-01 1.11712E-06 2.55734E+03 2.89843E-01 8.31097E-07 2.64000E+03 2.59635E-01 6.83094E-07 2.73623E+03 2.30293E-01 5.20194E-07 2.83687E+03 2.04826E-01 4.04397E-07 2.93935E+03 1.83147E-01 3.16037E-07 3.04858E+03 1.63724E-01 2.47763E-07 3.16766E+03 1.45936E-01 1.93538E-07 3.31219E+03 1.28029E-01 1.47236E-07 3.47596E+03 1.11477E-01 1.11363E-07 3.66549E+03 9.60672E-02 8.32135E-08 3.85720E+03 8.35713E-02 6.36293E-08 4.04028E+03 7.38582E-02 4.98083E-08 4.26860E+03 6.40703E-02 3.71078E-08 4.48358E+03 5.66593E-02 2.84208E-08 4.66546E+03 5.14406E-02 2.27576E-08 4.82062E+03 4.75947E-02 1.88801E-08 4.99103E+03 4.38949E-02 1.54298E-08 5.19490E+03 4.00555E-02 1.22795E-08 5.37820E+03 3.70471E-02 1.01754E-08 5.52080E+03 3.49479E-02 8.89237E-09 5.69220E+03 3.26631E-02 7.64450E-09 5.96050E+03 2.95307E-02 6.26750E-09 6.23030E+03 2.68407E-02 5.30847E-09 6.54200E+03 2.42125E-02 4.38599E-09 6.77860E+03 2.25066E-02 3.66712E-09 7.13090E+03 2.03302E-02 2.37024E-09 7.44960E+03 1.86090E-02 5.98009E-10 7.82670E+03 1.66367E-02 -1.49897E-09
start › cdms › coldhardware › thermometer › u09212_curve