UMN CDMS Wiki archive
start › cdms › coldhardware › thermometer › u09212_34a
 Name: RX-102B-RS-0.02B
 Serial Number: U09212
 Format: 4             ; Log Ohms/Kelvin
 Limit: 40.0
 Coefficient: 1        ; Negative
 Point 1: 3.07171,45.0
 Point 2: 3.07755,40.0
 Point 3: 3.08028,37.9
 Point 4: 3.08304,35.9
 Point 5: 3.08584,34.0
 Point 6: 3.08881,32.1
 Point 7: 3.09197,30.2
 Point 8: 3.09518,28.4
 Point 9: 3.09861,26.6
 Point 10: 3.10207,24.9
 Point 11: 3.10579,23.2
 Point 12: 3.10955,21.6
 Point 13: 3.11334,20.1
 Point 14: 3.11376,19.95
 Point 15: 3.11509,19.45
 Point 16: 3.11688,18.80
 Point 17: 3.11873,18.15
 Point 18: 3.12065,17.50
 Point 19: 3.12264,16.85
 Point 20: 3.12471,16.20
 Point 21: 3.12685,15.55
 Point 22: 3.12908,14.90
 Point 23: 3.13122,14.30
 Point 24: 3.13344,13.70
 Point 25: 3.13575,13.10
 Point 26: 3.13815,12.50
 Point 27: 3.14065,11.90
 Point 28: 3.14326,11.30
 Point 29: 3.14575,10.75
 Point 30: 3.14835,10.20
 Point 31: 3.15107, 9.65
 Point 32: 3.15366, 9.15
 Point 33: 3.15637, 8.65
 Point 34: 3.15921, 8.15
 Point 35: 3.16192, 7.70
 Point 36: 3.16445, 7.30
 Point 37: 3.16711, 6.90
 Point 38: 3.16993, 6.50
 Point 39: 3.17257, 6.15
 Point 40: 3.17536, 5.80
 Point 41: 3.17826, 5.46
 Point 42: 3.18137, 5.12
 Point 43: 3.18452, 4.80
 Point 44: 3.18791, 4.48
 Point 45: 3.19112, 4.20
 Point 46: 3.19397, 3.97
 Point 47: 3.19648, 3.78
 Point 48: 3.19915, 3.59
 Point 49: 3.20186, 3.41
 Point 50: 3.20459, 3.24
 Point 51: 3.20750, 3.07
 Point 52: 3.21064, 2.90
 Point 53: 3.21382, 2.74
 Point 54: 3.21703, 2.59
 Point 55: 3.22050, 2.44
 Point 56: 3.22427, 2.29
 Point 57: 3.22810, 2.15
 Point 58: 3.23198, 2.02
 Point 59: 3.23620, 1.89
 Point 60: 3.24085, 1.76
 Point 61: 3.24557, 1.64
 Point 62: 3.25077, 1.52
 Point 63: 3.25607, 1.41
 Point 64: 3.26194, 1.30
 Point 65: 3.26730, 1.21
 Point 66: 3.26891,1.185
 Point 67: 3.27118,1.150
 Point 68: 3.27426,1.105
 Point 69: 3.27751,1.060
 Point 70: 3.28096,1.015
 Point 71: 3.28420,0.975
 Point 72: 3.28763,0.935
 Point 73: 3.29127,0.895
 Point 74: 3.29514,0.855
 Point 75: 3.29926,0.815
 Point 76: 3.30312,0.780
 Point 77: 3.30722,0.745
 Point 78: 3.31161,0.710
 Point 79: 3.31630,0.675
 Point 80: 3.32134,0.640
 Point 81: 3.32677,0.605
 Point 82: 3.33264,0.570
 Point 83: 3.33900,0.535
 Point 84: 3.34490,0.505
 Point 85: 3.34972,0.482
 Point 86: 3.35460,0.460
 Point 87: 3.35930,0.440
 Point 88: 3.36427,0.420
 Point 89: 3.36901,0.402
 Point 90: 3.37350,0.386
 Point 91: 3.37832,0.370
 Point 92: 3.38355,0.354
 Point 93: 3.39056,0.334
 Point 94: 3.39798,0.314
 Point 95: 3.40516,0.296
 Point 96: 3.41248,0.279
 Point 97: 3.41992,0.263
 Point 98: 3.42744,0.248
 Point 99: 3.43556,0.233
 Point 100: 3.44438,0.218
 Point 101: 3.45333,0.204
 Point 102: 3.46307,0.190
 Point 103: 3.47297,0.177
 Point 104: 3.48377,0.164
 Point 105: 3.49567,0.151
 Point 106: 3.50780,0.139
 Point 107: 3.52121,0.127
 Point 108: 3.53490,0.116
 Point 109: 3.55014,0.105
 Point 110: 3.56656,0.095
 Point 111: 3.58338,0.085
 Point 112: 3.60150,0.076
 Point 113: 3.62119,0.068
 Point 114: 3.64277,0.060
 Point 115: 3.66660,0.052
 Point 116: 3.69313,0.045
 Point 117: 3.72275,0.039
 Point 118: 3.75576,0.033
 Point 119: 3.79266,0.027
 Point 120: 3.83507,0.022
 Point 121: 3.85684,0.020
 Point 122: 3.89358,0.017