CDMS cold hardware
Below is mostly a reorganization of UCB/SLAC/UMN documents for convenience.
150mm Si Detector
30mK stage
| File | Description |
|---|---|
| mc_bottom_shield_flange_6in-1.pdf | Bottom flange of 30mK can. |
| mc_bottom_shield_tube_6in-1.pdf | 30mK can tube. |
| mc_mc3_6in-1.pdf | Top flange of 30mK can. |
| mc_and_100mk_assembly.pdf | 30mK can assembly with 100mK stage. |
1cm module
Detector
| File | Description |
|---|---|
| FAKE_ZIP_DETECTOR.pdf | Brass piece dimensioned like detector but with hole cut out of center to keep mass similar to a Ge detector; used for fit checks |
Detector housing
| File | Description |
|---|---|
| DETECTOR_HOUSING_REVB1T.pdf | 1cm Detector housing fabrication drawing |
| DETECTOR_CLAMPS_REVB1.pdf | Detector clamps fabrication drawing |
| DETECTOR_CLAMP_SPACER_REVB.pdf | Detector clamp spacer fabrication drawing |
| DET_HOUSING_BOTLID_REVB.pdf | Detector housing bottom (charge side) lid fabrication drawing |
| DET_HOUSING_TOPLID_REVB1.pdf | Detector housing top (phonon side) lid fabrication drawing |
1 inch module
Detector
| File | Description |
|---|---|
| NEW_DETECTOR_DRAWING.PDF | Detector crystal dimension drawing |
Detector housing
| File | Description |
|---|---|
| 1inchDetectorHousingB.pdf | 1 inch Detector housing fabrication drawing |
| 1inchDetectorAdaptorRingA.pdf | Fabrication drawing for adapter ring to combine with 1 inch housing for a full 3 1cm detector spacing (allows existing side coaxes to be used with more than one 1 inch detector) |
Detector Assembly
| File | Description |
|---|---|
| 1inchAssemblyRevB.pdf | 1“ Detector assembly drawing |
Tower
Tower parts
| File | Description |
|---|---|
| 4K_FLOOR_REVB1.PDF | 4 Kelvin floor fabrication drawing |
| 600MK_FLOOR_REVB2.PDF | 600 milliKelvin floor fabrication drawing |
| 50MK_FLOOR_REVB1.PDF | 50 milliKelvin floor fabrication drawing |
| 10MK_FLOOR_REVB2.pdf | 10 milliKelvin floor fabrication drawing |
| CARBON_TUBES_REVB.PDF | Carbon tubes fabrication drawing |
| TOWERCOAX_COVERS_REVB.PDF | Floor cover plates fabrication drawing |
| towerheatsinksrevB.1.pdf | Tower heatsink printed circuit boards documentation package |
| CONNECTOR_TUBE_REVB2.PDF | Tower connector tube |
| CONNECTOR_LID_REVB3.pdf | Tower connector tube lid |
| SQUID_SPOOL_REVB1.PDF | SQUID spool |
| SQUID_SPOOL_COVER_REVB.PDF | SQUID spool lid |
| LidWaferClamp.pdf | Si wafer clamp |
Assembly
| File | Description |
|---|---|
| TOWERASSY_11.pdf | |
| TOWER_3D.PDF |