Running goldsluice and developing an algorithm

goldsluice is the fast half of the project: pulse-reduction kernels in Rust, each with a Python mirror that is the readable definition. You develop in Python on ordinary arrays, then port the same computation to Rust; a test makes sure the two never disagree. It lives in its own repository, villano-lab/goldsluice (start with its README.md; PORTING.md is the reference for the port). Two algorithms exist: peak (the largest ADC value and the largest current above the baseline of each trace) and max_time (the time of the largest sample); max_time is the worked example below, and the smaller model to copy.

1. One-time setup

You need Rust, Python 3.9 or newer and a Python environment (the darkmatter_cli_env of the student guides is fine).

  • Rust: install from https://rustup.rs. On Windows also install the Visual Studio Build Tools with the workload “Desktop development with C++” (it supplies the linker); then run rustup-init.exe with the defaults. On macOS the Xcode command line tools are enough (xcode-select --install); on Linux a C compiler (gcc). Check in a new terminal:

rustc --version
cargo --version
  • Build and install goldsluice in your environment (from the repository, with the environment active):

cd goldsluice
python -m pip install maturin pytest numpy
maturin develop --release
python -m pytest tests
cargo test

maturin develop --release compiles the Rust and installs the package in place (editable: Python files you change take effect at once; after a change in src/ run it again). Always --release when you time anything: a debug build is ten times slower or more.

2. Run it

from goldsluice import run, compare

out = run("peak", traces, glitch_samples=10, pretrigger_samples=1000, amps_per_adc=1.5e-9)
out["adc_max"]          # largest raw ADC value, one number per trace
out["current_max"]      # largest current above the pretrigger mean, in amps

traces is an array of shape (n_events, n_samples) for one channel. From a goldpan Events that is a loop over its channels:

for name in ev.detector.channel_names():
    out = run("peak", ev.trace(name), glitch_samples=10,
              pretrigger_samples=1000, amps_per_adc=AMPS_PER_ADC)

Nothing about the readout is assumed: no parameter has a default (amps_per_adc, the glitch and pretrigger lengths are the readout’s, and a wrong silent value would change every result). The input is converted to C-contiguous float64 (a copy for uint16 traces: keep a converted array if you call run many times). run(..., backend="python") runs the mirror instead of the Rust kernel. Bad parameters raise ValueError, with the same message from either backend.

3. Time it

Two numbers, on purpose:

print(compare("peak", traces, glitch_samples=10,
              pretrigger_samples=1000, amps_per_adc=1.5e-9))
cargo bench

compare is what a user sees: the Python call, the conversion, the output arrays, against the mirror (timed on its first 200 traces and scaled, because it is slow). cargo bench times the Rust kernel alone, with no Python: that is the number to optimise. RAYON_NUM_THREADS=1 gives the single-thread time. Reference (20000 traces of 4096 samples, one PC, release build): Rust 29 ms with all cores, 149 ms on one thread, Python 15.7 s.

4. Develop an algorithm: the worked example max_time

The time of the largest sample (as goldpan.algorithms.max_time). It is in the repository (reference/max_time.py, src/max_time.rs): read it next to this page (both are in the repository). The steps are the same for every algorithm; replace max_time by your name.

Step 1. Write the mirror, python/goldsluice/reference/max_time.py (in the goldsluice repository), in the kernel subset: one trace in, plain loops, no numpy inside kernel.

NAME = "max_time"
OUTPUTS = ("max_time_s",)

def problem(n_samples, sample_period_s):
    if not sample_period_s > 0:
        return "sample_period_s must be positive"
    return None

def kernel(trace, sample_period_s):
    best = 0
    for i in range(1, len(trace)):
        if trace[i] > trace[best]:
            best = i
    return (best * sample_period_s,)

Also in the module: cases(), the standard inputs [(traces, params), ...] (an ordinary case, an edge case such as two equal maxima, a trap); bad_cases(), inputs that must be refused; and goldpan_expected(traces, params), the same numbers from goldpan’s own function (goldpan.algorithms.max_time here), or NO_GOLDPAN = "why goldpan has none". The parity test requires one of the two, so a quantity is never defined twice with different numbers. Register it: from . import max_time, peak and ALL = [peak, max_time] in reference/__init__.py.

Step 2. Develop and check it in Python alone. It works at once, with no Rust:

run("max_time", traces, backend="python", sample_period_s=0.8e-6)

Compare it with an existing function (here goldpan.algorithms.max_time) and fix the idea in Python, where a mistake is cheap. Do not write Rust before this is right.

Step 3. Port it, src/max_time.rs: the same lines in Rust (the table in PORTING.md has the equivalents).

pub struct MaxTimeParams { pub sample_period_s: f64 }

pub fn problem(_n_samples: usize, p: &MaxTimeParams) -> Option<String> {
    if p.sample_period_s.is_nan() || p.sample_period_s <= 0.0 {
        return Some("sample_period_s must be positive".to_string());
    }
    None
}

pub fn max_time_one(trace: &[f64], p: &MaxTimeParams) -> f64 {
    let mut best = 0;
    for i in 1..trace.len() {
        if trace[i] > trace[best] { best = i; }
    }
    best as f64 * p.sample_period_s
}

Add max_time_many (the loop over traces with traces.par_chunks(n_samples)) and a unit test, copying src/peak.rs. In src/lib.rs add pub mod max_time;, a max_time_py function that copies peak_py (it checks problem, then calls the kernel with the GIL released) and one m.add_function(wrap_pyfunction!(max_time_py, m)?)?; line. Add the kernel to benches/kernels.rs.

Step 4. Build and test.

maturin develop --release
python -m pytest tests
cargo test
cargo clippy --all-targets -- -D warnings
cargo fmt

tests/test_parity.py needs nothing from you: it finds the new algorithm and checks that it has both versions, that they agree on cases() to a relative 1e-12, that both refuse bad_cases() with the same message, and that they agree with goldpan. A failure names the algorithm and the output.

Step 5. Time it and open the pull request. compare("max_time", ...) and cargo bench; put both numbers, and the checklist of PORTING.md, in the pull request, with a line under [Unreleased] in CHANGELOG.md. The pull request goes into develop like any other (AGENTS.md); a workflow builds and tests it on Windows, macOS and Linux.

5. The traps the example met

Trap

What happens

A float in an error message

Python writes 0.0 and 1e-06, Rust writes 0 and 0.000001: the two messages differ and the parity test fails. Name the parameter and the rule, with no number.

not x > 0 against x <= 0.0

They differ for NaN, which the first refuses and the second lets through. In Rust test x.is_nan() as well (clippy refuses !(x > 0.0)). Put a NaN in bad_cases().

Order of a sum

Floating-point sums depend on the order. Sum front to back in both; the test allows 1e-12 relative, which is rounding and not a different formula.

Ties and NaN in max

Keep the first of equal maxima in both (a strict >). Rust’s f64::max ignores NaN, Python’s max does not: decide, and test it.

Forgetting to rebuild

A change in src/ does nothing until maturin develop --release is run again; a change in the mirror takes effect at once.

Timing a debug build

maturin develop without --release is ten times slower or more.

When an algorithm is naturally array-shaped (an FFT, a fit), PORTING.md ends with what to do: ask before you choose that route.

An algorithm that returns a trace (a filter, a baseline subtraction) sets KIND = "trace" and OUTPUTS = ("trace",) in its mirror. Its kernel returns a list of n_samples floats instead of a tuple; the Rust function returns a 1-tuple holding a 2-D float64 array of the shape of traces; run gives {"trace": array}. An optional ATOL (default 0) is the absolute tolerance, beside the relative 1e-12, of the parity test and of the comparison with goldpan: set it by measuring the largest disagreement on cases(). Examples: subtract_line (loops only) and lowpass (an FFT, so its mirror is a numpy reference). PORTING.md has the details.