Index A | B | C | D | E | F | G | H | I | K | L | M | N | O | P | Q | R | S | T | U | W | Z A active() (in module goldpan.cuts) add_record() (in module goldpan.registry) algorithm (goldpan.dataset.Step attribute) alias_function() (in module goldpan.legacy) all_channels() (in module goldpan.channels) applies_to() (goldpan.dataset.Step method) attach() (in module goldpan.adapters.rq) available() (in module goldpan.adapters) B base (goldpan.dataset.Source attribute) baseline_subtract() (in module goldpan.operations) bline() (in module goldpan.quantities) bline_1000() (in module goldpan.quantities) board_input (goldpan.channels.Channel attribute) branches() (in module goldpan.adapters.rq_root) bstd() (in module goldpan.quantities) bstd_1000() (in module goldpan.quantities) C cache_clear() (in module goldpan.rqdata) cache_dir() (in module goldpan.rqdata) cache_info() (in module goldpan.rqdata) calibration_line() (in module goldpan.rq_cuts) Channel (class in goldpan.channels) channel (goldpan.channels.Channel attribute) channel() (goldpan.data.Detector method) channel_info() (in module goldpan.channels) channel_label() (in module goldpan.channels) channel_max_amps() (in module goldpan.rq_cuts) channel_name() (in module goldpan.channels) channel_names() (goldpan.data.Detector method) (goldpan.dataset.Step method) ChannelInfo (class in goldpan.data) channels (goldpan.data.Detector attribute) (goldpan.dataset.Step attribute) channels_with_role() (goldpan.data.Detector method) check_adapter() (in module goldpan.testing) clip() (in module goldpan.operations) compare() (in module goldpan.registry) compute() (in module goldpan.algorithms) concatenate() (goldpan.data.Events static method) config (goldpan.data.Segment attribute) (goldpan.registry.ReadoutRecord attribute) config() (goldpan.data.Readout method) D data (goldpan.adapters.midas.RawEvent attribute) Dataset (class in goldpan.dataset) dataset (goldpan.rqdata.RQData attribute) DatasetSpec (class in goldpan.dataset) dcrc (goldpan.channels.Channel attribute) DCRC_RUN76 (in module goldpan.config) dead_channel() (in module goldpan.cuts) description (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) Detector (class in goldpan.data) detector (goldpan.channels.Channel attribute) (goldpan.data.Events attribute) (goldpan.dataset.Source attribute) detector() (goldpan.registry.Registry method) detector_index() (in module goldpan.io) detector_record (goldpan.dataset.Source attribute) DetectorRecord (class in goldpan.registry) detectors() (goldpan.registry.Registry method) (in module goldpan.adapters.midas) downsample() (in module goldpan.algorithms) downsampled_config() (in module goldpan.algorithms) dump() (in module goldpan.dataset) dumps() (in module goldpan.dataset) E ENV_OUTPUT (in module goldpan.dataset) ENV_VAR (in module goldpan.registry) event_id (goldpan.adapters.midas.RawEvent attribute) event_id() (in module goldpan.io) Events (class in goldpan.data) evidence (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) excursion_band() (in module goldpan.cuts) excursion_band_AI() (in module goldpan.cuts) excursion_band_loose() (in module goldpan.cuts) excursion_band_rq() (in module goldpan.rq_cuts) excursion_below_percentile() (in module goldpan.cuts) excursion_duration() (in module goldpan.quantities) excursion_ratio() (in module goldpan.quantities) excursion_ratio_rq() (in module goldpan.rq_cuts) expand_branches() (in module goldpan.rqdata) F files (goldpan.rqdata.RQData attribute) files() (goldpan.dataset.Source method) filter_by_detector() (in module goldpan.io) find_channel() (in module goldpan.channels) find_file() (in module goldpan.rqdata) find_files() (in module goldpan.rqdata) fingerprint() (in module goldpan.dataset) flat_namespace() (in module goldpan.legacy) FolderSource (class in goldpan.registry) format (goldpan.dataset.Source attribute) FORMAT_VERSION (in module goldpan.dataset) (in module goldpan.registry) frequencies_hz() (in module goldpan.quantities) from_arrays() (goldpan.data.Events class method) G glitch_samples (goldpan.config.PulseConfig attribute) (goldpan.legacy.PulseConfig attribute) goldpan module goldpan.adapters module goldpan.adapters.idx module goldpan.adapters.midas module goldpan.adapters.parquet module goldpan.adapters.rq module goldpan.adapters.rq_root module goldpan.algorithms module goldpan.archive module goldpan.channels module goldpan.config module goldpan.cuts module goldpan.data module goldpan.dataset module goldpan.io module goldpan.legacy module goldpan.operations module goldpan.quantities module goldpan.registry module goldpan.rq_cuts module goldpan.rqdata module goldpan.runmeta module goldpan.status module goldpan.testing module groups() (in module goldpan.runmeta) H half_max_time_us() (in module goldpan.quantities) has_detector() (goldpan.registry.Registry method) has_readout() (goldpan.registry.Registry method) hv_output (goldpan.channels.Channel attribute) I input (goldpan.data.ChannelInfo attribute) (goldpan.dataset.Step attribute) integral() (in module goldpan.algorithms) iter_chunks() (in module goldpan.adapters.midas) (in module goldpan.adapters.parquet) (in module goldpan.adapters.rq_root) iter_events() (goldpan.dataset.Dataset method) (in module goldpan.adapters.midas) K KEY_COLUMNS (in module goldpan.data) L letter (goldpan.channels.Channel attribute) list_archive() (in module goldpan.archive) list_statuses() (in module goldpan.status) load() (goldpan.registry.FolderSource method) (in module goldpan.dataset) (in module goldpan.registry) (in module goldpan.rqdata) load_channel_batch() (in module goldpan.io) load_channel_batch_multi() (in module goldpan.io) load_good_events() (in module goldpan.archive) log_excursion_ratio() (in module goldpan.quantities) log_excursion_ratio_rq() (in module goldpan.rq_cuts) looks_like_pulse() (in module goldpan.cuts) loose_randoms() (in module goldpan.rq_cuts) lowpass() (in module goldpan.algorithms) M MAIN (in module goldpan.data) main() (goldpan.data.Segment class method) mask (goldpan.adapters.midas.RawEvent attribute) max_deviation() (in module goldpan.quantities) MAX_RQ_UA_TO_A (in module goldpan.rq_cuts) max_time() (in module goldpan.algorithms) meta (goldpan.data.Events attribute) metadata (goldpan.dataset.DatasetSpec attribute) MidasFormatError missing() (in module goldpan.adapters.rq_root) module goldpan goldpan.adapters goldpan.adapters.idx goldpan.adapters.midas goldpan.adapters.parquet goldpan.adapters.rq goldpan.adapters.rq_root goldpan.algorithms goldpan.archive goldpan.channels goldpan.config goldpan.cuts goldpan.data goldpan.dataset goldpan.io goldpan.legacy goldpan.operations goldpan.quantities goldpan.registry goldpan.rq_cuts goldpan.rqdata goldpan.runmeta goldpan.status goldpan.testing N n_events (goldpan.data.Events property) n_samples (goldpan.data.Segment attribute) NAI_TRIGGER (in module goldpan.channels) name (goldpan.adapters.midas.OdbDetector attribute) (goldpan.channels.Channel attribute) (goldpan.data.ChannelInfo attribute) (goldpan.data.Detector attribute) (goldpan.data.Segment attribute) (goldpan.dataset.DatasetSpec attribute) (goldpan.dataset.Source attribute) (goldpan.dataset.Step attribute) (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) NOT_CONNECTED (in module goldpan.channels) number (goldpan.adapters.midas.OdbDetector attribute) (goldpan.registry.DetectorRecord attribute) O odb_name (goldpan.registry.DetectorRecord attribute) OdbDetector (class in goldpan.adapters.midas) open() (goldpan.dataset.Dataset class method) origin (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) output (goldpan.dataset.DatasetSpec attribute) output_format (goldpan.dataset.DatasetSpec attribute) output_status() (in module goldpan.dataset) P params (goldpan.dataset.Step attribute) parse_odb() (in module goldpan.adapters.midas) parse_odb_detectors() (in module goldpan.adapters.midas) path (goldpan.dataset.DatasetSpec attribute) patterns (goldpan.dataset.Source attribute) per_event() (in module goldpan.runmeta) PHONON_CHANNELS (in module goldpan.rqdata) phonon_log_ratios() (in module goldpan.rq_cuts) pileup_randoms() (in module goldpan.rq_cuts) plane (goldpan.adapters.midas.OdbDetector attribute) (goldpan.registry.DetectorRecord attribute) power_spectrum() (in module goldpan.quantities) pretrigger_mean() (in module goldpan.quantities) pretrigger_samples (goldpan.config.PulseConfig attribute) (goldpan.legacy.PulseConfig attribute) pretrigger_std() (in module goldpan.quantities) processed() (goldpan.dataset.Dataset method) pt_std_proxy() (in module goldpan.rq_cuts) pulse_max() (in module goldpan.algorithms) PulseConfig (class in goldpan.config) (class in goldpan.legacy) Q quantities (goldpan.data.Events attribute) quiet_baseline() (in module goldpan.cuts) R randoms() (in module goldpan.cuts) ratio_band() (in module goldpan.cuts) raw (goldpan.dataset.DatasetSpec attribute) RawEvent (class in goldpan.adapters.midas) read (goldpan.dataset.Source attribute) (goldpan.registry.DetectorRecord attribute) read() (goldpan.dataset.Dataset method) (in module goldpan.adapters) (in module goldpan.adapters.idx) (in module goldpan.adapters.midas) (in module goldpan.adapters.parquet) (in module goldpan.adapters.rq_root) read_defaults() (goldpan.registry.DetectorRecord method) read_raw() (in module goldpan.dataset) read_table() (in module goldpan.runmeta) Readout (class in goldpan.data) readout (goldpan.adapters.midas.OdbDetector attribute) (goldpan.data.Detector attribute) (goldpan.dataset.Source attribute) (goldpan.registry.DetectorRecord attribute) readout() (goldpan.registry.Registry method) readout_config() (goldpan.registry.Registry method) ReadoutRecord (class in goldpan.registry) readouts() (goldpan.registry.Registry method) real_triggers() (in module goldpan.cuts) record_text() (in module goldpan.registry) register() (in module goldpan.adapters) Registry (class in goldpan.registry) registry (goldpan.dataset.DatasetSpec attribute) registry_entry() (in module goldpan.adapters.midas) resolve() (goldpan.dataset.Step method) REVISION (in module goldpan.adapters.idx) (in module goldpan.adapters.midas) (in module goldpan.adapters.parquet) (in module goldpan.adapters.rq_root) revision() (in module goldpan.adapters) rise_sample() (in module goldpan.quantities) rise_time() (in module goldpan.algorithms) role (goldpan.channels.Channel attribute) (goldpan.data.ChannelInfo attribute) root_detector (goldpan.dataset.DatasetSpec attribute) RQData (class in goldpan.rqdata) run_metadata() (goldpan.dataset.DatasetSpec method) S sample_period_s (goldpan.config.PulseConfig attribute) (goldpan.legacy.PulseConfig attribute) sample_rate_hz (goldpan.config.PulseConfig property) save_good_events() (in module goldpan.archive) Segment (class in goldpan.data) segment() (goldpan.data.Readout method) segments (goldpan.data.Readout attribute) select() (goldpan.data.Events method) SENSOR (in module goldpan.channels) sensor_channels() (in module goldpan.channels) serial (goldpan.adapters.midas.RawEvent attribute) series (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) series_list() (in module goldpan.rqdata) side (goldpan.channels.Channel attribute) single() (goldpan.data.Readout class method) skipped (goldpan.rqdata.RQData attribute) Source (class in goldpan.dataset) source() (goldpan.dataset.DatasetSpec method) sources (goldpan.dataset.DatasetSpec attribute) (goldpan.dataset.Step attribute) start_s (goldpan.data.Segment attribute) status (goldpan.registry.DetectorRecord attribute) (goldpan.registry.ReadoutRecord attribute) status() (in module goldpan.status) STATUS_FILE (in module goldpan.dataset) Step (class in goldpan.dataset) step_record() (in module goldpan.dataset) steps (goldpan.dataset.DatasetSpec attribute) stream_matches() (in module goldpan.adapters.parquet) suffix (goldpan.dataset.Step attribute) T tight_randoms() (in module goldpan.rq_cuts) time_axis() (goldpan.data.Events method) (goldpan.data.Readout method) TIME_COLUMN (in module goldpan.data) timestamp (goldpan.adapters.midas.RawEvent attribute) tower (goldpan.adapters.midas.OdbDetector attribute) (goldpan.registry.DetectorRecord attribute) trace() (goldpan.data.Events method) traces (goldpan.data.Events attribute) TRIGGER_CODES (in module goldpan.adapters.rq_root) trigger_types() (in module goldpan.io) triggered_physics() (in module goldpan.rq_cuts) trim_glitch() (in module goldpan.operations) type_code (goldpan.adapters.midas.OdbDetector attribute) (goldpan.registry.DetectorRecord attribute) U unit (goldpan.data.ChannelInfo attribute) unpack_scd0() (in module goldpan.adapters.midas) W with_quantities() (goldpan.data.Events method) write() (in module goldpan.adapters.parquet) (in module goldpan.adapters.rq_root) write_table() (in module goldpan.runmeta) Z Z7 (in module goldpan.config) Z7_PHONON_CHANNELS (in module goldpan.rq_cuts)