Run76 series catalog: non-PuBe series and availability on nsdf-cli

Note 1 · Author(s): Anthony Villano · 14 Sept 2026 (revised 24 Sept 2026) · Status: Complete (2026-09-14)

Code Repository

Files this note rests on, each pinned to the commit that last changed it:

Question

Which Run76 data exists, and how much of it can actually be downloaded from NSDF, in particular anything other than PuBe?

How “available” was checked

In nsdf-cli a “file” is one dump of a series, e.g. 07221203_2025_F0001; a series is a run of many dumps F0001, F0002, … Two checks were made:

Result: only PuBe is downloadable

The Run76 sheet lists 235 series. Sizes are download sizes (the whole dump folder, compressed; a dump is about four times larger once loaded into memory).

Source (column C, source / shield)Series in run logSeries on nsdfDumps (files)Size (GiB)
PuBe17013038,5661,549.7
Am42000.0
Na-222000.0
No source recorded (mostly tests)21000.0
Total23513038,5661,549.7

All 130 available series are PuBe, and none of the 65 non-PuBe series (42 Am, 2 Na-22, 21 with no source recorded) are on NSDF. The 130 hold 38,566 dumps, 1,550 GiB (1.51 TiB).

Has it changed since the table was last made?

No. The series counts, and which series are available, are identical to the previous version of this table. Checked against each source:

Limit of the live check: for series without a listing, only the first five dumps were tried. Of the 130 known series, 129 start at F0001 and one at F0002, so a series that exists only under higher dump numbers would be missed.

A filter in the run log hides 62 series

The Run76 sheet has an Excel filter switched on for its trigger column. It hides 62 rows: exactly the 62 DCRC3-triggered series. Opened in Excel, the sheet shows only 173 of the 235 series, and any list made from what is visible would be missing those 62.

Every count in this note includes the hidden rows. The reader used here returns hidden rows like any others, and this was checked against the raw file rather than assumed: 237 rows, 62 marked hidden, and 235 of the rows are series (the last row is a formula helper, not a series). The script prints the filter range and the number of hidden rows on every run, and the CSV marks each series the filter hides (hidden_by_filter). All 130 available series are among the 173 visible ones, so the filter hides only series that are not on NSDF. The workbook itself was not changed.

What the 130 available series look like

Which PuBe series are not there

Of the 170 PuBe series, 40 are not on NSDF. They differ from the 130 that are in how they were triggered: 39 of the 40 use a DCRC3 trigger and one has no trigger recorded, whereas none of the 130 available series does. Across the whole run log, none of the 62 DCRC3-triggered series is on NSDF, whatever its source; these are also the 62 rows the sheet’s filter hides. The trigger is not the whole story, though: the 20 Am series triggered on DCRC1 or NaI are missing too.

The processing columns (proc0, proc1) do not explain it: 106 processed series are on NSDF and 86 processed ones are not. The reason these series were not uploaded is not in the data available here.

The 130 available series

One row per available series (all 235 are in the CSV). Scroll for the full list; “Downloaded” is the number of dumps of that series present in ~/idx on the machine this was run on.

SeriesHV (V)TriggerDuration (min)DumpsSize (GiB)Downloaded
07220702_1055-197.3NaI171120.10—
07220703_2012-197.3NaI90900.49—
07220703_2151-197.3NaI7087083.79—
07220704_1444-197.3NaI91920.53—
07220704_1630-197.3NaI2712711.53—
07220704_2111-197.3NaI5522011.12—
07220705_0646-197.3NaI2682681.52—
07220706_1112-197.3NaI1001000.74—
07220706_1303-197.3NaI2101093.91—
07220706_1659-197.3NaI2182183.23—
07220706_2048-197.3NaI5755758.50—
07220707_0639-197.3NaI—30.03—
07220707_0644-197.3NaI2892894.23—
07220707_1758-197.3NaI2272273.40—
07220707_2205-197.3NaI6116118.97—
07220708_0833-197.3NaI1601602.33—
07220708_1632-197.4NaI3323322.53—
07220708_2217-197.4NaI6661270.98—
07220709_0935-197.3NaI2731681.29—
07220709_18070NaI2152041.50—
07220709_21440NaI20522,05215.03—
07220711_1709-197.3NaI10221,0227.69—
07220712_1324———30.13—
07220712_1336——20720717.27—
07220826_1219-4DCRC1pB 1081814.33—
07220826_1536-20.7DCRC1pB 1084844.42—
07220826_2007-65DCRC1pB 1079794.21—
07220827_1153-84.3DCRC1pB 1090904.17—
07220830_1247———60.00—
07220830_1724-85.3DCRC1pB 1060602.52—
07220830_1829-85.2NaI1131132.13—
07220830_2033-85DCRC1pB 1044441.62—
07220830_2118-84.8NaI72372314.02—
07220831_0955-84DCRC1pB 10530.11—
07220831_1002-81DCRC1pB 101031035.45—
07220831_1151-84.2NaI4074077.88—
07220831_1846-83.9DCRC1pB 1094944.68—
07220906_15100DCRC1pB 1053533.92—
07220906_16140NaI1831833.44—
07220909_11150——191.30—
07220909_12000——140.94—
07220909_12560DCRC1pB 1044443.14—
07220909_13400SiHV&NaI18218213.90—
07220909_16480NaI1961963.69—
07220909_2023-20.7DCRC1pB 1038383.04—
07220909_2102-20.9NaI25250.50—
07220909_2243-20.9NaI79679615.86—
07220910_1210-20.7DCRC1pB 1034342.75—
07220910_1517-4.1DCRC1pB 1049493.84—
07220910_1608-4.1NaI98298217.33—
07220912_1955-66.8DCRC1pB 1070705.81—
07220912_2107-66.8NaI65765713.57—
07220913_0814-66.8DCRC1pB 1082826.86—
07220913_145797.9DCRC1pB 1045453.63—
07220913_154697.9NaI71871814.76—
07220914_113397.8DCRC1pB 1043423.35—
07220916_2059-79.4DCRC1pB 1059594.56—
07220916_2200-79.7NaI74774714.42—
07220917_1039-80.2DCRC1pB 101031038.14—
07220917_1225-80.3NaI53153110.29—
07220917_2125-80.3DCRC1pB 1030302.29—
07220917_2155-80.3NaI2732735.29—
07220919_1723-80.3DCRC1pB 1044443.28—
07220919_1808-80.6NaI440.07—
07220919_2012-80.7NaI1111112.12—
07220920_0925-80DCRC1pB 1042423.09—
07220920_1007-80NaI63663612.25—
07220920_2052-78.9DCRC1pB 1045453.30—
07220920_2138-78.9NaI68968913.09—
07220921_0915-81.1DCRC1pB 1077775.83—
07220921_1034-81.3NaI3033035.77—
07220921_1541-81.4DCRC1pB 1049493.68—
07220921_1631-81.4NaI1381382.62—
07220921_1851———40.07—
07220921_2055-81.4DCRC1pB 1075875810.42—
07221001_2314-82.5DCRC1pA 231223,122248.87—
07221017_1600-82.5DCRC1pA 2—52941.77—
07221019_1741-82.6DCRC1pB 1046463.66—
07221019_1832-82.6NaI2022026.04—
07221019_2157-82.4DCRC1pB 1042423.45—
07221019_2240-82.5NaI53353315.92—
07221020_0849-82.4DCRC1pB 1063624.96—
07221020_0954-82.4NaI52452415.75—
07221020_1846-82.4DCRC1pB 1043432.63—
07221020_1948-82.5NaI84184117.68—
07221021_1001-82.3DCRC1pB 1084844.95—
07221021_1126-82.4NaI3683687.68—
07221025_1751-82.1DCRC1pB 10—1198.63—
07221025_1956-82.1NaI62162118.99—
07221026_0951-82.1DCRC1pB 1057574.56—
07221026_1049-82.1NaI64664619.67—
07221026_2145-82.1DCRC1pB 1039393.07—
07221026_2224-82.1NaI64064019.58—
07221027_0915-82.1DCRC1pB 1044443.49—
07221027_0959-82.1NaI36636110.96—
07221102_15550DCRC1pB 1019019012.11—
07221102_21320DCRC1pB 10—76448.87—
07221106_23200DCRC1pB 10—80250.26—
07221111_2153-82.2DCRC1pB 1055554.58—
07221111_2249-82.2NaI63463452.17—
07221112_0943-82.2DCRC1pB 101011018.59—
07221112_1127-82.1NaI66666652.53—
07221112_2249-82.1DCRC1pB 1069695.81—
07221113_0000-82.1NaI70270257.90—
07221113_1159-82DCRC1pB 1045453.50—
07221114_2141-81.8DCRC1pB 1037373.05—
07221114_2223-81.8NaI61161133.51—
07221115_0845-81.7DCRC1pB 1033332.63—
07221115_0919-81.7NaI69569536.85—
07221115_2109-81.7DCRC1pB 1051514.13—
07221115_2201-81.7NaI70770738.85—
07221116_1003-81.6DCRC1pB 1045453.56—
07221116_1048-81.7NaI1671679.09—
07221118_1404-81.6DCRC1pA 227527521.99—
07221118_1850-81.6DCRC1pA 289989971.14—
07221119_1016-81.5DCRC1pA 223120216.37—
07221121_22140DCRC1pA 277977956.15—
07221124_1408-8.3DCRC1pA 267674.83—
07221124_1603-16.3DCRC1pA 284846.20—
07221124_1748-24DCRC1pA 21181189.12—
07221124_2022-34DCRC1pA 297977.33—
07221124_2331-34DCRC1pA 10036136120.92—
07221125_05470DCRC1pA 10053253219.54—
07221201_01180DCRC1pA 100—64717.53—
07221203_1255-46.6DCRC1pA 268685.26—
07221203_1418-53.5DCRC1pA 21081087.71—
07221203_1622-63.4DCRC1pA 268685.29—
07221203_1744-73DCRC1pA 264644.89—
07221203_1906-79.9DCRC1pA 262624.65—
07221203_2025-83.2DCRC1pA 230301.895 of 30

Local copy: five empty stub folders

Only one Run76 series is downloaded: 07221203_2025, dumps F0001–F0005 of its 30. ~/idx also holds five empty folders for two series that are in the run log but not on NSDF: 07221022_1630_F0001–F0004 and 07221206_1738_F0001. They are left over from failed download attempts, since the download command creates the folder before fetching. This matters because it also skips any name whose folder already exists, so a repeated download of one of these names would silently do nothing even if the files were added later. They have not been deleted.

Am/lead series in Runs 72–74

R76/am_lead_series.csv lists the series tagged Am/lead in the neighbouring runs: 317 series (Run72: 8, Run73: 175, Run74: 134), none of them on NSDF, as above. This is a different set from the 42 Run76 Am series, and it does not include any Run76 series.

Lesson: read column C, and mind the filter. The Am tag lives in column C (source / shield) of the run-log sheets, not in the type column, and the sheet carries an Excel AutoFilter that hides rows (currently 62 of them, above). A first pass that read type missed the Am series entirely; the numbers above come from reading column C directly, with every row included whatever the filter hides. When reading a run-log sheet, check its filter state and hidden-row count each time.

Status / Next Steps